DSF22
UNIQUE MONITORING TERMINAL
33
INSTALLATION AND SETUP GUIDE
P51 Fuel data procession depth
Description
This parameter defines fuel data procession depth. Less value means
deeper data procession.
More information available in section “
Measured fuel data procession
”.
Options
Parameter can be read and modified.
Used values
1
-
250
Default value
30
Comments
Not recommended to use value less than 20, this can raise slow reaction
on fuel level changes during driving.
Example
To read parameter:
GET P51
To set parameter:
SET P51 40
Response from device:
P51: 40
P52 Fuel measurement conditions.
Description
This parameter defines conditions under which allowed measurement of
the fuel level.
Options
Parameter can be read and modified.
Used values
0
–
Fuel level measurement always allowed.
1
–
Fuel level measurement allowed only when ignition is ON
2
–
Fuel level measurement allowed only when ignition is OFF
Default value
0
Comments
Example
To read parameter:
GET P52
To set parameter:
SET P52 2
Response from device:
P52: 2