P45 Fuel theft alarm (Tank 2)
Description
This parameter defines a work mode for fuel theft alarm for Tank 2. In case
if set to 0, then fuel theft alarm is disabled. In parameter is greater than 0,
then fuel theft alarm becomes enabled, value equals to threshold of level
changes to trigger fuel theft alert. Greater value = less “sensitivity”
Options
Parameter can be read and modified.
Used values
0
–
Fuel theft alarm disabled.
1
-
250
–
Fuel theft alarm enabled, trigger threshold value set
Maximal value allowed -
250
Default value
0
Comments
Example
To read parameter:
GET P45
To set parameter:
SET P45 2
Response from device:
P45: 2
P46 Fuel level change direction (Tank 2)
Description
This parameter defines a fuel level change direction to trigger a fuel theft
alert for Tank 2. Parameter is related to ADC (Analog Digital Converter)
value, depending of vehicle’s fuel sensor type (normal or inverted),
required value must be selected.
Options
Parameter can be read and modified.
Used values
0
–
Fuel theft alert will be triggered in both cases (by increasing or
decreasing of ADC measurement)
1
–
Fuel theft alert will be triggered only if ADC measurement will be
increased
2
–
Fuel theft alert will be triggered only if ADC measurement will be
decreased
Default value
0
Comments
Example
To read parameter:
GET P46
To set parameter:
SET P46 2
Response from device:
P46: 2