![Digital Systems DSF22 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/digital-systems/dsf22/dsf22_installation-and-setup-manual_2499563029.webp)
DSF22
UNIQUE MONITORING TERMINAL
29
INSTALLATION AND SETUP GUIDE
P41 Fuel theft alert mode
Description
This parameter defines working mode of fuel theft alarm. There are three
possible options to inform about detected fuel theft.
Options
Parameter can be read and modified.
Used values
0
–
Alert will be sent to server via GPRS
1
–
Alert will be sent to server and predefined phone numbers (via SMS)
2
–
Alert will be sent to server and predefined phone numbers (via SMS),
digital output Nr1 will be activated for 20 seconds (for external siren
control)
Default value
0
Comments
Example
To read parameter:
GET P41
To set parameter:
SET P41 1
Response from device:
P41: 1
P42 User phone number Nr1
Description
This parameter defines a user Nr1 phone number for SMS alert reception.
Options
Parameter can be read and modified.
Used values
ASCII digits 0-9, maximal length is 32 bytes
Note!!!
Phone number must be entered with “+” sign and country code,
otherwise SMS alert will not be sent.
Default value
(empty)
Comments
Example
To read parameter:
GET P42
To set parameter:
SET P42 +37198765432
Response from device:
P42: +37198765432