Digital Systems DSF22 Скачать руководство пользователя страница 16

 

 

DSF22 

UNIQUE MONITORING TERMINAL

 

16 

INSTALLATION AND SETUP GUIDE 

List of all parameters. 

Parameter 

Description 

Options 

Response 

Default value 

P10 

APN name 

Read and Set 

Yes 

internet 

P11 

Server IP address 

Read and Set 

Yes 

92.63.86.53 

P12 

Server PORT 

Read and Set 

Yes 

3432 

P13 

Communication protocol 

Read and Set 

Yes 

P14 

GPRS Login 

Read and Set 

Yes 

(empty) 

P15 

GPRS Password 

Read and Set 

Yes 

(empty) 

P16 

GPRS 

Read and Set 

Yes 

P17 

Roaming  

Read and Set 

Yes 

P18 

GPRS connection limiter 

Read and Set 

Yes 

15 

P19 

Server response wait time 

Read and Set 

Yes 

20 

P20 

GPS angle threshold 

Read and Set 

Yes 

P21 

GPS start speed threshold 

Read and Set 

Yes 

P22 

GPS time threshold 

Read and Set 

Yes 

180 

P23 

PING interval in home network 

Read and Set 

Yes 

60 

P24 

New event wait time 

Read and Set 

Yes 

P25 

PING interval in roaming network 

Read and Set 

Yes 

60 

P26 

Static STOP coordinates 

Read and Set 

Yes 

P27 

Anti-sabotage function 

Read and Set 

Yes 

P28 

GPS signal interruption SMS alert 

Read and Set 

Yes 

P30 

Digital output 1 

Read and Set 

Yes 

P31 

Fuel data source 

Read and Set 

Yes 

P32 

Fuel measurement frequency 

Read and Set 

Yes 

15 

P33 

Fuel sensor imitation mode 

Read and Set 

Yes 

P35 

Universal digital pin working mode 

Read and Set 

Yes 

P36 

Digital output 2 

Read and Set 

Yes 

P40 

Fuel theft alarm (Tank1) 

Read and Set 

Yes 

P41 

Fuel theft alert mode 

Read and Set 

Yes 

P42 

User’s phone number

 Nr1 

Read and Set 

Yes 

(empty) 

P43 

Level change direction (Tank1) 

Read and Set 

Yes 

P44 

Fuel theft alarm activation time 

Read and Set 

Yes 

20 

P45 

Fuel theft alarm (Tank2) 

Read and Set 

Yes 

P46 

Level change direction (Tank2) 

Read and Set 

Yes 

P48 

User’s phone number Nr2

 

Read and Set 

Yes 

(empty) 

P50 

Fuel data processing 

Read and Set 

Yes 

P51 

Fuel data processing depth 

Read and Set 

Yes 

30 

P52 

Fuel measurement conditions 

Read and Set 

Yes 

P53 

Valid fuel data wait time 

Read and Set 

Yes 

15 

P60 

Vehicle’s battery supervisor

 

Read and Set 

Yes 

P61 

Vehicle engine status report 

Read and Set 

Yes 

P62 

Digital input change SMS alert 

Read and Set 

Yes 

GPS 

Read current GPS data 

Read 

Yes 

GSM 

Read GSM network data 

Read 

Yes 

ID 

Read device ID and FW version 

Read 

Yes 

STATUS 

Read device control register 

Read 

Yes 

ERASE 

Erase data memory 

Set 

Yes 

CELLPOS 

Read position based on GSM cells 

Read 

Yes 

Содержание DSF22

Страница 1: ...DSF22 INSTALLATION AND SETUP GUIDE 1 7 2015...

Страница 2: ...nection diagram for additional fuel sensor 9 Settings related to additional fuel sensor usage 9 Measured fuel data procession 10 How data procession works 10 Settings related to fuel data processing 1...

Страница 3: ...DSF22 UNIQUE MONITORING TERMINAL 3 INSTALLATION AND SETUP GUIDE List of all parameters 16 Description of parameters 17 Technical parameters 42...

Страница 4: ...al pin Green This is universal pin by default it s configured as digital input can be used to monitor a status of electrical equipment in the vehicle such as lights door opening etc Can be configured...

Страница 5: ...disconnected it is possible to connect external backup battery Using this possibility terminal will continue working after vehicle s battery disconnection and if it s necessary terminal can send aler...

Страница 6: ...ts set P42 and or P48 3 Enable digital Input status change alert define alert condition P62 set to 2 From this moment digital input status change alert is enabled in case if voltage in green wire will...

Страница 7: ...rawback of this method is precision of measurements it can range from 1 up to 10 and it is related to vehicle s fuel sensor type and condition Usual connection diagram for standard fuel sensor Picture...

Страница 8: ...l pin is configured as digital output P35 1 then this pin cannot be used as digital input at the same time Settings related to standard fuel sensor usage Parameter Required value Comments P31 0 Enable...

Страница 9: ...awback is limited possibilities to install additional sensors in most cases it is possible to install additional sensors only on trucks tractors and construction machinery no possibilities for passeng...

Страница 10: ...ehicle position based on accelerometer driving speed and driving angle Based on these parameters terminal makes data procession and averaging as result a correct fuel data will be sent to the monitori...

Страница 11: ...rt blinks GPS module ready accurate position available GSM module status Green LED Condition of LED Description of operating mode Constantly OFF GSM module switched OFF Constantly ON GSM module is not...

Страница 12: ...for alarm triggering 2 Set alarm mode by setting parameter P41 this parameter is common for both fuel tanks alarms Available options a If P41 0 alert will be send only to server no SMS will be sent b...

Страница 13: ...pervisor in this case driver will be informed about voltage drop via SMS message How it works Each time ignition is switched OFF terminal starts to monitor a vehicle s battery voltage In case if volta...

Страница 14: ...inal makes only one GPRS session and keeps it open while ignition is switched on however by different reasons GPRS session can be terminated from operator side or bad network coverage In case if GPRS...

Страница 15: ...S commands All SMS commands must be written with capital letters in case if wrong SMS command has been sent device will ignore it Read commands Read commands always starts with GET followed by space a...

Страница 16: ...P31 Fuel data source Read and Set Yes 0 P32 Fuel measurement frequency Read and Set Yes 15 P33 Fuel sensor imitation mode Read and Set Yes 0 P35 Universal digital pin working mode Read and Set Yes 0 P...

Страница 17: ...be modified Almost all parameters are stored in the non volatile memory in case if power loss parameter value will not be changed P10 APN name Description APN Access Point Name used to established GPR...

Страница 18: ...Defines communication protocol between terminal and server Options Parameter can be read and modified Used values 0 TCP 1 UDP Default value 0 Example To read parameter GET P13 To set parameter SET P13...

Страница 19: ...SET P15 wap Response from device P15 wap P16 GPRS connectivity Description Enable or Disable GPRS connectivity Options Parameter can be read and modified Used values 0 GPRS Disabled 1 GPRS Enabled Def...

Страница 20: ...Comments Example To read parameter GET P18 To set parameter SET P18 50 Response from device P18 50 P19 Server response wait time Description Each data packet sent from terminal to the server must be...

Страница 21: ...value 4 Comments Example To read parameter GET P20 To set parameter SET P20 5 Response from device P20 5 P21 GPS start speed threshold Description Defines GPS start speed km h In case if vehicle speed...

Страница 22: ...fault value 180 Comments Example To read parameter GET P22 To set parameter SET P22 100 Response from device P22 100 P23 PING time Description Defines PING interval minutes in home networks also calle...

Страница 23: ...0 Event wait time enabled value equals to seconds for new event waiting Maximal value allowed 250 Default value 5 Comments Example To read parameter GET P24 To set parameter SET P24 10 Response from d...

Страница 24: ...scription This function allows detecting situations when vehicle driver are trying to interrupt GPS signal by disconnecting GPS antenna or by jamming GPS signal In case if this function is enabled and...

Страница 25: ...To read parameter GET P28 To set parameter SET P28 1 Response from device P28 1 P30 Digital output 1 Description This parameter defines condition of digital output Nr1 It is useful in cases when some...

Страница 26: ...from device P31 1 P32 Fuel measurement frequency Description This parameter defines a fuel measurement frequency during driving time Ignition is switched ON Each unit equals to 32 milliseconds if nec...

Страница 27: ...imitation enabled Default value 0 Comments Example To read parameter GET P33 To set parameter SET P33 1 Response from device P33 1 P35 Universal digital pin working mode Description This parameter de...

Страница 28: ...s or restart this parameter will be set to 0 Example To read parameter GET P36 To set parameter SET P36 1 Response from device P36 1 P40 Fuel theft alarm Tank 1 Description This parameter defines a wo...

Страница 29: ...ers via SMS digital output Nr1 will be activated for 20 seconds for external siren control Default value 0 Comments Example To read parameter GET P41 To set parameter SET P41 1 Response from device P4...

Страница 30: ...ly if ADC measurement will be decreased Default value 0 Comments Example To read parameter GET P43 To set parameter SET P43 2 Response from device P43 2 P44 Fuel theft alarm activation time Descriptio...

Страница 31: ...To read parameter GET P45 To set parameter SET P45 2 Response from device P45 2 P46 Fuel level change direction Tank 2 Description This parameter defines a fuel level change direction to trigger a fue...

Страница 32: ...ents Example To read parameter GET P48 To set parameter SET P48 37198765432 Response from device P48 37198765432 P50 Fuel data processing Description This parameter enables disables fuel data processi...

Страница 33: ...n raise slow reaction on fuel level changes during driving Example To read parameter GET P51 To set parameter SET P51 40 Response from device P51 40 P52 Fuel measurement conditions Description This pa...

Страница 34: ...ed to use value greater than 20 this can raise slow reaction on fuel level changes during driving Example To read parameter GET P53 To set parameter SET P53 5 Response from device P53 5 P60 Vehicle ba...

Страница 35: ...lt value 0 Comments Example To read parameter GET P61 To set parameter SET P61 2 Response from device P61 2 P62 Digital input changes SMS alert Description This parameter enables disables SMS alert fo...

Страница 36: ...position 3 good position SAT Number of satellites used for navigation Default value Comments Example To read parameter GET GPS Response from device LAT 54 2345678 LONG 24 1234567 SPEED 0 KM H FIX 3 SA...

Страница 37: ...22 s n 02109 v1 01 ERASE Erase internal memory Description This command performs full erase of internal data memory all unsent data will be erased Options Parameter is write only Used values Default v...

Страница 38: ...nition 0 off 1 on IN1 Status of digital input 0 off 1 on FIX GPS signal quality Default value Example To read parameter GET STATUS Response from device UNS 00004 GPRS 000 RES 002 MEM 000 GPS 002 POW 1...

Страница 39: ...odule Options Parameter is read only Used values Default value Comments If P31 1 actual value represents voltage mV in analog input Example To read parameter GET FUEL Response from device FUEL 1735 TX...

Страница 40: ...Example To read parameter GET TX2 To set parameter SET TX2 Fuel theft was detected Response from device TX2 Fuel theft was detected TX3 SMS alert text 3 Description This command defines SMS alert text...

Страница 41: ...l to defined phone numbers in case of GPS signal interruption Options Parameter can be read and modified Used values Use Latin characters only Default value GPS signal lost Comments Max allowed length...

Страница 42: ...s load mA max 500 GPS Number of GPS channels 50 Tracking sensitivity dBm 160 GPS accuracy meters 2 GPS Cold start seconds 32 Hot start seconds 1 GSM GSM bands 4 Operating frequency MHz 855 900 1800 19...

Отзывы: