Appendix C: Mode Switch Bank Settings and Optional Installations
C-2
DLE28-MA User’s Guide
Figure C-1 shows the location of the mode switches and the switch
settings for normal operation.
Figure C-1
DLE28-MA Mode Switch
Location/Component Layout
Switch definitions and positions are as follows:
•
Switches 1 through 4 – For DIGITAL use only.
•
Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disables Autobaud sensing
and sets the COM port to 9600 baud for Local Management sessions.
•
Switch 6 – Forced BootP. Changing the position of this switch (i.e.,
moving the switch from one position to the other) clears download
information from NVRAM and forces the DLE28-MA to download a
new image file from a BootP server after power to the chassis is
restored.