7–2
Site Preparation and Maintenance
NOTE
On power up, the seven-segment display will show an
“8”. Allow about 3 minutes to elapse before determin-
ing the state of the display.
Table 7–1:
Display/Indications
Device
Definition
State
Indication
Corrective
Action
System OK LED
Diagnostic
On
Off
Flashing
Self-test passed
1
Fatal error
1
Nonfatal error
Section 7.4
Section 7.5
Seven-segment
display
Status/
diagnostic
Off
“C”, “d”, “n”
Flashing
“3”
Rotating
segment
pattern
No power or
display broken
SIM failure
Fatal error
Load request
backoff
DECserver 700
software
executing
Section 7.2
Section 7.3
Section 6.4
Section 7.6
1
A fatal error means that the network access server cannot function. A nonfatal error means
that the network access server can function with reduced capability (for example, one serial
port not working).
7.2 Seven-Segment Display Off and System OK LED Off
Problem
Power is not reaching the DECserver 700 hardware.
Correction: Secure the power cable at the DECserver 700 and at the wall outlet and
check the fuse in the power cable plug (if applicable).
Содержание DECserver 700-08
Страница 1: ...Part Number EK DSRVW MG B01 DECserver 700 Site Preparation and Maintenance Hardware Owner s Manual...
Страница 20: ......
Страница 38: ......
Страница 48: ......
Страница 60: ...5 12 Site Preparation and Maintenance Figure 5 8 Replacing the Covers LKG 7304 91I 1 2...
Страница 64: ...6 4 Site Preparation and Maintenance Figure 6 2 Inserting the Flash RAM Card LKG 7305 92I...
Страница 77: ...Printed in U S A...