![DIGITAL DELAY Mega 475 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/digital-delay/mega-475/mega-475_instruction-manual_2498391061.webp)
- 61 -
Additional Wiring Help
Wiring Three Wire Push-buttons
Most push-buttons only have two wires. If your
push-button has three wires you will only need to use two of
them. The two wires are the Common ( C ) and the
Normally Open ( N O ). The Normally Closed ( N C ) wire
is not used.
High Current Relay
When higher currents are required, an external relay
needs to be wired between the output and the device.
To wire the additional relay;
Connect pin 85 to the desired terminal strip output.
Connect pin 86 to ground.
Connect pin 87 to power.
Connect pin 30 to the device.
Grounding Relay
If the device to be controlled needs Ground, instead
of +12 Volts, an external relay needs to be wired between the
output and the device.
To wire the additional relay for ground;
Connect pin 85 to the S.F.O. terminal.
Connect pin 86 and 87 to Ground.
Connect pin 30 to the device.