22
PM-000145 - PD/SD HIGH POWERED PLANETARY DRIVE MANUAL - MARCH 2019
9.
Connect the case drain to the case drain on your machine. If your machine has a case tap, ensure the case tap is turned on.
Failure to connect the case drain will severely damage the motor and void all warranty. The Case Drain hose is already fitted
to the unit Hydraulic motor and must be unravelled. This Case drain hose must return directly to Hydraulic Oil Reservoir on
the Parent machine. There can be no valving or restrictions in the line and the hose must be minimum ½” ID. The loose end of this
case drain line must have a fitting fitted to match the fitting on the Parent machine.
10. VARIABLE FOOT CONTROL - Host machines used to power High Powered PD and SD Drive units must have their Auxiliary
Circuit controlled with a variable foot control. This foot control gives the operator the ability to ease the power on and off avoiding
shock loading which will cause potential expensive damage to the Hydraulic motor and Gearbox.
11. FILTRATION/CONTAMINATION - All High Powered PD and SD Drive units are fitted with Piston Hydraulic Motors which
require filtration of 10 micron fitted to both A & B pressure hoses. We recommend these filters be permanently fitted to the
Drive unit so any contamination entering the system while connecting/disconnecting hoses is caught before entering the hydraulic
motor.
12. With the unit lying horizontally on the ground connect the auger, screw anchor or extension or core barrel. ENSURE THE AUGER
PIN AND SAFETY CLIP ARE INSTALLED CORRECTLY. The machine is now ready for use.
13. If augering, check the auger teeth and pilots are not worn. Ensure all worn parts are replaced. Worn parts will become ineffective
and severely diminish the overall performance of the Planetary Drive and Auger.
PLEASE NOTE: ALTERING, TAMPERING OR DISMANTLING ANY PART OF THE DIGGA UNIT WITHOUT WRITTEN PERMISSION
FROM DIGGA WILL VOID ANY WARRANTY.
WARNING: ENSURE THAT THERE ARE NO QUICK RELEASE COUPLERS IN THE CASE DRAIN LINE
OR T-CONNECTORS. OPERATION WITHOUT CASE DRAIN WILL CAUSE MOTOR FAILURE
8 COMMISIONING PROCEDURE
Содержание PD 30 HP-7
Страница 1: ...1 OPERATORS MANUAL PD SD SINGLE SPEED HIGH POWERED DRIVES PM 000145...
Страница 2: ...2 PM 000145 PD SD HIGH POWERED PLANETARY DRIVE MANUAL MARCH 2019...
Страница 42: ...42 PM 000145 PD SD HIGH POWERED PLANETARY DRIVE MANUAL MARCH 2019 NOTES...
Страница 43: ...43 NOTES...
Страница 44: ...44 PM 000145 PD SD HIGH POWERED PLANETARY DRIVE MANUAL MARCH 2019 PM 000145...