18
Option 3:
Manual operation of all valves via the 3 programs.
Turn the to MANUAL mode.
Program A appears first with above the valves operates by the program with
the word OFF and the icon. To select A, B, and C program, press until ABC
program appears with word STOP, with above the valves and the . To open
the valves with the programmed time in A, B a C press the or .
All valves that have irrigation duration in program A, B and C will start open one
after the other. The open valve icon will appear with the word RUN and if master
valve is active the icon will also appear.
18. MODE X SUPPORT PROGRAM FOR PUMP, LIGHTING
AND FOUNTAINS
Program X allows the user to activate a fountain, garden lighting and others.
Program X can be activated only in the WEEKLY/ CYCLIC mode. Using this program,
master valve, rain sensor, rain off and budget are not used and will not influence
this program, but can be operating by the other programs. Use of this program will
require a relay interface kit with 24 VAC and max of 50 mA.
NOTE: Program X operated the last valve of the 4, 6 and 8 station controllers.
NOTE: If the relay is connected to any circuit higher than 24-volts, it must
be located in its own high voltage junction box in accordance with local
electrical code.