background image

8

 8. CONNECTING THE TRANSFORMER WIRE TO THE CONTROLLER

WARNING:  Do not plug transformer into power source until the controller is mounted.

After connecting all valve wires and installing the battery, you are ready to connect the 

transformer. Use only the supplied transformer, or a transformer with 110 VAC power input, 

50 Hertz and 24 VAC output. 
1.  First, connect the transformer wire to the two terminals marked “24V”. (see figure below) 

(Polarity does not matter).

2.  Plug the transformer to 110 Volt electrical outlets. 

Note: If power is 

interrupted to the 

controller when 

irrigation is on, the 

valve will close 

automatically 

and irrigation will 

stop, although 

the controller will 

continue to operate 

per the program.

 9. PROGRAMMING

General Information 

The GQ-AC controller is ready to program. Lift the cover and remove the plastic sheet that 

protecting the LCD display. At this stage the user needs to program the controller.

Before programming the controller:

The GQ-AC controller has three irrigation programs, A, B, and C. In addition, it has an 

additional support program, program X that can also be activated. The three programs (A, 

B, and C) can be used to operate all the valves. In each program, days of watering can be 

selected in which all the valves activated by one of the three programs.  Start-time is set 

only for the first valve on the system, with the irrigation duration being defined for each valve 

separately. The valves are opened in sequence per their number as shown on the display 

screen. When the first valve shuts down, the second valve opens up and so on.  At any one 

time only one valve operates.  If the three programs are used (A + B + C) with irrigation times 

which overlap, program A will open first and only after it shuts down, program B will open, 

then program C opens last. Any of the valves can be operated by any of the three programs, 

with differing durations under each program. 

Содержание GQ-AC4

Страница 1: ...ays in odd even or every day rotation Operate four 4 six 6 or eight 8 stations with master valve or pump start Five 5 buttons with a large dial and large integrated liquid crystal display LCD for easy...

Страница 2: ...graming 8 10 Setting current time day of week and date 10 11 Time format switching between AM PM and 24 hour 10 12 Selecting watering frequency 11 12 13 Setting a start time 13 14 Programming water du...

Страница 3: ...rrigation programs and features that meet today s irrigation needs The controller illustration shows the front with the programming buttons dials and the terminals 1 Dial selector used to select the d...

Страница 4: ...ontroller slightly below eye level see example of mounting sketch Mount the controller to the wall with 6 or 8 screws not included Note If installing on drywall install screw anchors not included see...

Страница 5: ...ctions to the terminals are tight and firm WARNING Do not connect more then one valve wire to each terminal 5 CONNECTING A MASTER VALVE OR PUMP START RELAY 24 VAC master valves can be attached at the...

Страница 6: ...ns for calibrating the sensor 2 When the sensor is activated a sensor icon appears on the display In that mode it prevents the valves from being opened NOTE The regular mode on the screen for sensor i...

Страница 7: ...battery compartment and replace the cover see 3 4 The dial selector is on OFF and the screen display will show OF F blinking and an AC icon if the transformer is not plugged into the wall socket NOTE...

Страница 8: ...ng the LCD display At this stage the user needs to program the controller Before programming the controller The GQ AC controller has three irrigation programs A B and C In addition it has an additiona...

Страница 9: ...be used Data increment button decreased lowers the value of the selected parameter example hours selected are changed from 06 00 to 05 00 Data increment button increased raises the value of the select...

Страница 10: ...minute using or Press the the year month date appear with the YEAR blinking Press the or and set the year Press the the month appears with the MONTH digit blinking Press the or and set the month Repea...

Страница 11: ...ext cyclic mode with 1 30 days and last ODD or EVEN modes Weekly Program Example Program the controller to operate on Wednesday Thursday Friday an Saturday Turn the to WEEKLY CYCLIC mode If not in a w...

Страница 12: ...s to select EVEN mode the appears under EVEN and the day of the week to water arrow appears under every day Select the day on which there will be no irrigation Press and the day of the week to water a...

Страница 13: ...the desired start time hour 7 please note and select AM or PM Press the minute is blinking press or to set the desired start time minute 30 Press for additional start time and repeat the steps if need...

Страница 14: ...main open Up to 4 hours of watering can be selected for each valve on each program in 1 minute increments Turn the to DURATION mode The screen with the program used A B or C the time is set to 0 00 th...

Страница 15: ...tically adjust the previously programmed durations according to the specified budget Turn the to WATER BUDGET mode Press until the program used appears 100 will appear with the program selected and ab...

Страница 16: ...B or C the above the active valves the icon and 00 Press and the 00 DAYS is blinking Press or and set the desired number of irrigation days suspension from 0 240 days Repeat the steps for each active...

Страница 17: ...ption 2 Open one valve via the MANUAL Turn the to MANUAL mode Program A appears first with above the valves operates by the program with the word OFF and the icon To open a specific valve in the progr...

Страница 18: ...ter valve is active the icon will also appear 18 MODE X SUPPORT PROGRAM FOR PUMP LIGHTING AND FOUNTAINS Program X allows the user to activate a fountain garden lighting and others Program X can be act...

Страница 19: ...rn the to TEST mode A number that represents the number of valves appears at the center to the right of the screen with 4 for four station 6 for six station and 8 for eight station The controller vers...

Страница 20: ...the display with a countdown showing irrigation time remaining If one of the programs is in OFF the symbol will appear If budget is used the icon will appear If backup battery is low battery warning...

Страница 21: ...l need reprogramming 22 LOW BATTERY WARNING Lack of AC Power When for any reason electric power is not reaching the controller an icon for lack of power will appear This will indicate that the control...

Страница 22: ...n in power Check power source system or faulty battery the transformer or replace the battery Sensor symbol permanently blinking The sensor bridge is Replace sensor or and valve does not open disconne...

Страница 23: ...G CORPORATION There are no warranties which extend beyond the description on the face hereof In the case of purchase of the product for use other than for irrigation purposes DIG CORPORATION hereby di...

Страница 24: ...able to answer questions in English and Spanish from 8 00 AM to 5 00 PM PST Monday Friday except holidays at 800 322 9146 Questions in English and Spanish can be e mailed to questions digcorp com or f...