OPERATING
Frame Base Tapered Mount
2. Insert the lock pin through the hole on the
tapered frame mount to secure the guard.
3. For guards 36” and larger, place a lock
washer and then a flat washer onto the
blade guard screw. Fit the screw through
the slot near the back of the guard and
through the hole on the frame base, and
secure the guard to the frame using the
provided wrench.
4. Connect the water supply hose to the blade
guard.
Removing the Blade Guard
Always remove the blade guard with the blade
off the saw.
WARNING
When removing a guard 48” or larger, use a
hoist to avoid serious injury.
1. Disconnect the water supply hose from the
blade guard.
2. Remove the rear bolt from the blade guard
and frame base.
3. Remove the lock pin from the tapered
frame mount.
4. Use the handle on the blade guard to rock
the guard back and forth while lifting the
guard off the tapered frame mount.
Slurry Shield (Optional)
An optional slurry shield can be installed on the
right rear side of the saw. The shield can be
flipped down while cutting to minimize slurry
back spray or flipped up flush against the
upright when not in use.
Slurry Shield
Flange Guard
Install the flange guard over the blade flange
that is not in use.
Installing the Flange Guard
1. Fit the tapered mount on the back of the
flange guard onto the tapered mount on the
frame.
2. Insert the lock pin through the hole on the
tapered frame mount to secure the guard.
Flange Guard Installed
Removing the Flange Guard
1. Remove the lock pin from the tapered
frame mount.
2. Remove the flange guard from the tapered
frame mount.
30
Содержание CC5049D
Страница 1: ...CORE CUT OPERATOR S MANUAL CC5049D Rev 21 00 Part 1802721...
Страница 2: ......
Страница 8: ...INTRODUCTION CC5049D Controls 8...
Страница 11: ...INTRODUCTION CC5049D Specifications 11...
Страница 58: ...REFERENCES 58...
Страница 59: ...REFERENCES 59...
Страница 60: ...REFERENCES 60...
Страница 67: ......