Table 12 - 2 Operating Troubleshooting - Data
ITEM CONDITION/INDICATION
POSSIBLE MALFUNCTION
CORRECTIVE ACTION
1 Control Panel Inoperative
Control Panel not connected
properly or damaged
Check cable connection on rear of
AVCS.
Inspect cables and connectors for
damage, if damaged replace cables.
Control Panel unserviceable
Disconnect Control panel and access
AVCS using external computer
connection. If AVCS operates
normally, continue mission, notify
service maintenance
Control Processor MSG
indicator light lit
Turn off power to system and restart.
Test system operation
NOTE: the MSG light does
not always mean there is a
problem. The MSG light
indicates that something has
been written to the
processor’s log file.
Notify Service Maintenance
2
Control Panel functions
Non-operational
System needs to be reset
Turn off power to system and restart.
Test system operation
Notify Service Maintenance
END OF TASK
Содержание TM 95263 00
Страница 2: ......
Страница 8: ......
Страница 10: ......
Страница 16: ......
Страница 22: ......
Страница 28: ......
Страница 30: ......
Страница 31: ...DHS Systems LLC TM 95236 00 CHAPTER 2 OPERATOR INSTRUCTIONS FOR AVCS MINI...
Страница 32: ......
Страница 48: ......
Страница 86: ......
Страница 88: ......
Страница 90: ......
Страница 91: ...DHS Systems LLC TM 95236 00 CHAPTER 3 OPERATOR TROUBLESHOOTING PROCEDURES FOR AVCS MINI...
Страница 92: ......
Страница 100: ......
Страница 106: ......
Страница 107: ...DHS Systems LLC TM 95236 00 CHAPTER 4 OPERATOR MAINTENANCE INSTRUCTIONS FOR AVCS MINI...
Страница 108: ......
Страница 112: ......
Страница 116: ......
Страница 122: ......
Страница 123: ...DHS Systems LLC TM 95236 00 CHAPTER 5 SUPPORTING INFORMATION FOR AVCS MINI...
Страница 124: ......
Страница 130: ......
Страница 132: ......