31
PART 1 - QUICK INSTALLATION GUIDE
ELECTRICAL CONNECTIONS
Before making the connections, make sure that:
-
the ends of the line wires are not live.
-
the electric power supply network is protected by thermal magnet and differential
protection high-sensitivity type
(30 mA in class A for domestic application, class B for
industrial applications)
Ground connections must be in compliance with Standards.
LOOSEN
DO NOT REMOVE
POWER CONNECTIONS
-
Wire the motor cables U, V, W to the terminal “MOTOR”, as shown below
-
Wire the line cables R, S, T to the terminal “LINE”, as shown below
U
V
W
1
2
Ø V
+24V dc
2
1
POWER
SUPPLY
FAN
OUTPUT
Ø V
+24V dc
MOTOR
N
.O
.
C
4
3
2
1
INPUT
OUTPUT
C
N
.C
.
PRESS .SENS.
3
2
1
+
V
dc
4
- 2
0m
A
0
- 4
,5
V
Ø
V
Fl
ow
N
.O
.
Fl
ow
C
4 5
FLOW SENS.
LINE
R
S
T
ØV
D-
D+
ØV
D-
D+
RS485
CAUTION :
to overcome
problems associated with long cables
(between Inverter and
pump motor) , evaluate the application of inverter output sinusoidal filter. It aids smooth
running of motors eliminating negative effect of voltage peaks