30
GB/MT
31
GB/MT
Introduction
Please read these operating instructions thor-
oughly and carefully. They are part of this
product and contain important instructions
relating to its operation and handling. Please
always observe all safety instructions. Before
initial operation, please check that all parts are
fitted correctly. If you have any questions or
are unsure about handling of the device,
please contact the dealer or the service office.
Please keep these instructions in a safe place
and pass them on to anyone else intending to
use the device.
Proper use
The gas alarm indicates a leakage of methane,
propane or butane gas from appliances, lines,
etc. with a high-frequency tone and a flashing
red ALARM LED
c
. It is intended for use in
dry areas inside buildings, vehicles, caravans
and boats. The power supply is either by way
of the supplied 12 V DC mains adapter con-
nected to the 230 V ~ 50 Hz mains electricity
or by connection to the 12 V DC on-board
power supply system of a car, caravan or boat.
The device is for private use only. Any other
use or modification of the device constitutes
improper use and poses a serious risk of acci-
dent. The manufacturer is not liable for dam-
age caused by improper use or incorrect oper-
ation of the device. Before initial operation,
please read all operating instructions carefully
and refer to the page showing the illustrations.
Keep these operating instructions in a safe
place. Please pass on all supplied documents
along with the device to anyone else intending
to use it.
Pack contents
We supply the gas alarm with the following
components (see Fig. A ):
1x gas alarm
1x 12 V DC mains adapter
1x mounting fixture
2x fastening screws
2x wall plugs
1x operating instructions
Features
On the front of the casing (see Fig. A):
a
Front of casing
b
Piezo siren opening
c
ALARM LED
d
POWER LED
e
FAULT LED
f
12 V DC mains adapter connecting cable
On the rear of the casing (see Fig. B):
g
Rear of casing
h
Mounting fixture
i
12 V DC terminal screws
j
Cable guide
k
Side and lower sensor openings
Technical data
Gas alarm:
Power supply:
12 Volt DC (±10%)
mains adapter (deliv-
ered with the gas
alarm) or on-board
power supply system
Current consumption: max. 150 mA
Gas sensor:
hot-wire method
Sensitivity/alarm
threshold:
corresponds to a con-
centration of approx.
12 % of the relevant
lower explosive limit
Propane:
0.2 %
Butane:
0.17 %
Methane
(town gas/natural gas): 0.53 %
Alarm signal:
loud high-frequency
tone
Volume:
85 dB(A) 3m
Operating temperature: -10 °C to +40 °C
Relative air humidity: max. 95 %
Material:
ABS plastic
Dimensions:
35 x 85 x 85 m (h x w x l)
Weight:
approx. 100 g
Protection class:
III
Mains adapter (delivered with the gas
alarm):
Power supply:
230 V ~ 50 Hz
Current consumption:
60 mA
Current output:
12 Volt DC 300 mA
Connecting cable length: approx. 2 m
Safety instructions
The following instructions are for your own
safety and satisfaction when operating the GA
617 gas alarm. Please note that non-compli-
ance with these safety instructions can lead to
a serious risk of accident.