2.3.2.3 Connectors for TTL counter expansion:
ORION expansion board connector
(68-pin amplimite series)
The DEWE-ORION-0824-200 can be expanded with
8 additional counters or 32 digital inputs with TTL
input level. These boards are named with
DEWE-ORION-0824-202 (without CAN) or
DEWE-ORION-0824-203 (with CAN)
The pin assignment is shown in the schematic:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Counter
Input
+5 V
Source Ex_CNT0
Gate Ex_CNT0
Reserved
Ex_Out 0
Aux Ex_CNT1
Source Ex_CNT1
Gate Ex_CNT1
Ex_Out 1
-
GND
-
-
GND
-
-
Aux Ex_CNT7
GND
GND
GND
Gate Ex_CNT6
Source Ex_CNT6
-
GND
Source Ex_CNT5
-
GND
Source Ex_CNT4
-
GND
Source Ex_CNT3
-
GND
Source Ex_CNT2
Counter
Input
GND
GND
RS-485A
RS-485B
GND
Aux_Ex_CNT0
GND
GND
GND
-
-
GND
-
-
GND
GND
Gate Ex_CNT7
Source Ex_CNT7
-
Aux Ex_CNT6
GND
GND
Aux Ex_CNT5
Gate Ex_CNT5
GND
Aux Ex_CNT4
Gate Ex_CNT4
GND
Aux Ex_CNT3
Gate Ex_CNT3
GND
Aux Ex_CNT2
Gate Ex_CNT2
GND
Digital
Input
-
-
-
-
-
-
-
-
-
Ex_DI 1
Ex_DI 2
-
Ex_DI 5
Ex_DI 6
-
-
Ex_DI 10
Ex_DI 11
Ex_DI 12
Ex_DI 13
-
-
Ex_DI 17
Ex_DI 18
-
Ex_DI 21
Ex_DI 22
-
Ex_DI 25
Ex_DI 26
-
Ex_DI 29
Ex_DI 30
-
Digital
Input
-
-
-
-
-
-
-
-
-
Ex_DI 0
-
Ex_DI 3
Ex_DI 4
-
Ex_DI 7
Ex_DI 8
Ex_DI 9
-
-
-
Ex_DI 14
Ex_DI 15
Ex_DI 16
-
Ex_DI 19
Ex_DI 20
-
Ex_DI 23
Ex_DI 24
-
Ex_DI 27
Ex_DI 28
-
Ex_DI 31
68-pin Amplimite series
(AMP: 174339-5) SCSI II
Digital expansion Ex
Counter expansion
2.3.2.4 Signal connection for TTL counter expansion
Without any option the counter or digital inputs are wired to a 68 pin female connector on DEWETRON
instruments. An easy sensor connection possibility is given with ORION-CB-CNT8 connection box.
For direct connection of the sensor to the instrument various options for counter panels are available:
ORION-DIO-PANEL-1
These panels should be used if mainly counter/encoder signals will be measured. All eight counters are
wired to 7-pin Lemo connectors and Ex_DI 0 to Ex_DI 15 are connected to a DB37.
ORION-DIO-PANEL-2
All 32 digital inputs are wired to two DB37 connectors. Ex_CNT 0 and Ex_CNT 1 are connected to a 7-pin
Lemo. Therefore this panel is suitable if mainly standard digital inputs are requested.
ORION-DIO-PANEL-3
This option is similar to Panel-2 except the digital inputs are galvanically isolated. The two counter inputs are
not isolated.