OPTIONAL CORD CADDY
1. Each heater comes with optional cord caddy kit including screws, nuts, and instructions.
WHEEL AND HANDLE ASSEMBLY
Wheels and handles are found in the shipping carton along with mounting hardware. The
wheels, axle and mounting hardware are in a package.
1. Handles come pre-assembled on the tank. The transport handle and support foot simply
snap into place.
2. To assemble the wheels, first Install one of the large lock nut onto the end of the axle.
3. Slide one wheel onto the axle next to the nut, then one spacer.
4. Slide the partially assembled axle through the wheel support frame.
5. Slide the spacer onto the axle next to the wheel support.
6. Slide the wheel, then large last large lock nut onto the axle. Using two adjustable wrenches
hold both nuts and tighten. DO NOT OVERTIGHTEN
7. Install the caps over the lock nuts to finish the wheel assembly.
PREPARATION FOR OPERATION
1. Check the heater for possible shipping damage. If any is found, immediately
contact the manufacturer.
2. Follow all WARNINGS and Precautions found in this manual.
3. Fill the fuel tank with clean diesel. In extremely cold weather, condensation may
develop in the tank and it is recommended that a tablespoon of de-icer be added
for each gallon (4 liters) of fuel in the tank. When filling the heater, use at least 2
gallons (8 liters) of fuel. Be sure heater is level and do not overfill. Use a funnel or
can with a long fill spout.
IMPORTANT: Before filling fuel tank the first time or after extended storage periods, drain the fuel
tank of any moisture or condensation.
4. Locate heater at a safe distance from combustible materials.
HEATER START UP
1. Turn thermostat to lowest setting and make sure “On/Off” switch is “Off”.
2. Plug the heater into a grounded 230V, 50 Hz, 1 Ø outlet.
3. Start heater by pushing toggle switch to “On” position (light signifies switch is in
“On” position.)
4. Adjust thermostat to desired setting. Heater will cycle on/off as heat is required.
• In cold weather (below -12.2 °C ) starting may be improved by holding
a finger over the vent hole of the pump adjustment screw cap until the
heater starts.
• This unit is equipped with an interrupt circuit. The reset is integrated into
the “On/Off” switch. If the unit does not start, toggle the switch to “Off”,
wait 5 min, and toggle the switch to “On”
• EXTENSION CORD REQUIREMENTS: Up to 30.5 M use 16 awg conductor.
30.5 - 61.0 m use 14 awg conductor.
HEATER SHUT DOWN
Push “On/Off” switch to “Off” position. For extended shutdown, unplug heater
from power source.
HEATER RESTART AFTER SAFETY SHUTDOWN
1. Toggle switch to “OFF” position
2. Wait 5 minutes
3. Restart
Maintenance and Storage
WARNING: To prevent personal injury, unplug the heater from the wall outlet before servicing.
For maximum efficiency and trouble-free service, make the following periodic
maintenance, cleaning and inspections.
ADJUSTING PUMP PRESSURE
Due to varying fuel viscosities and normal component wear the pump pressure on
this heater may need to be adjusted.
FUEL PRESSURE ADJUSTMENT SCREW
(located at the rear of the heater)
PRESSURE GAUGE (If Equipped)