ACCESSORY/REPLACEMENT ITEMS
The following items can be purchased separately as accessories or replacement items for your 7305 Series DeVilbiss Suction Unit:
Description
Part No.
6’ Patient Tubing
6305D-611
12V DC power cord (1each)
7304D-619
1200 ml Reusable collection bottle (16 each)
7305D-601
800 ml Disposable collection bottle (48 each)
7305D-602
Switch mode AC to DC adapter/charger
7305P-613
12V DC high capacity rechargeable battery (1 each)
7305P-614
Carrying case
7305D-606
Replacement gauge
7305D-607
Bacteria filter (non-sterile) (12 pack)
7305D-608
Circuit board (7305P series & converted battery units)
7305P-610
Circuit board (7305D series)
7305D-610
High capacity battery conversion kit
7305P-620
(battery, 7305P-610 circuit board & battery tray)
Vacuum gauge test fixture
7304D-636
Hospital grade line cord (120 VAC)
099HD-614
Line cord for US
6710D-609
Line cord for Continental Europe
7305P-631
Filter, 800ml collection bottle, elbow & tubing package
7305D-603
1200ml bottle package
7305D-604
SET-UP
1. Connect either end of the 4" tubing to the tubing connector then connect the other end to the bacteria filter. Ensure that the clear side of
the bacteria filter is toward elbow and bottle when installing/re-installing. Do not reverse direction of filter.
2. The bacteria filter should then be connected to the 90˚ elbow connection, and the 90˚ connection should be connected to the top of the can-
ister lid where it says <Vacuum>.
3. The 6' patient tubing should be connected to the canister lid at the outlet labeled <Patient>.
4. Please assure that all connections are secure and without leaks before using.
5. Verify that unit is at desired suction level
before
beginning patient suction.
HOW TO OPERATE YOUR 7305 SERIES DEVILBISS SUCTION UNIT
Before connecting the unit to the AC adapter or 12V DC cord, make sure that the power switch located on the side of the unit is in the “Off”
position. Select power source desired.
LED Explanations:
L1- Green
– External power supplied to unit from AC power source or DC cord. Illuminated when external power is supplied.
L2 - Yellow
– Battery is being charged. Light will go out when battery is fully charged. (7305P Series only)
L3 - Red
– Low battery. Seek another power source and charge battery as soon as possible when light remains on continuous. (7305P Series
only)
AC OPERATION–
Plug the small connector of the AC adapter into the DC power input located on the side of the unit. Plug the AC end into a
grounded wall-outlet power source.
NOTE–
The power supply may become warm to the touch during charging or running of the unit. This is normal.
12V DC OPERATION–
(such as a car lighter receptacle). Plug the small connector of the DC power cord into the DC power input on the side of
the unit. Plug the large connector into the 12V DC power receptacle of the automobile.
BATTERY OPERATION–
Verify that your unit has an internal rechargeable battery; factory installed on models 7305P series or provider installed
on models 7305D series (installed as an option). To ensure proper operation from internal battery, fully charge the battery for 10-17 hours as
explained in the Battery Charging section. To operate the unit from an internal rechargeable battery, ensure that no external power sources are
plugged into the DC power input on the side of the unit.
Once the power source is selected, simply turn the unit “On” using the power switch located on the side of the unit. The power indicator light
(displayed on the top of the unit) will indicate which power source is being used by staying continuously lit when external power is connected.
A-704
4
E n g l i s h
A c c e s s o r y & R e p l a c e m e n t I t e m s / S e t - U p / O p e r a t i o n