- 14 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
Device Settings
This chapter lists the settings influencing the operation of the DB2003 but having no direct
influence on the monitored device, as well as its selection and connection.
There are two levels of login rights to the DB2003: as
admin
or as
user
. These are default
usernames, which can be changed. Each of them has its own password for access. Admin has full
access to the device and can remotely manage the monitored devices. The session is maximum 10
minutes long (subject to setup) and can be renewed. The admin session can be interrupted by an
SNMP user for a set operation.
User has limited rights. It can monitor but can not edit. It has no access to settings and cannot
change the operation mode of the DB2003 or influence monitored devices. Its session can be set to
no time limits but can be interrupted by admin or by an SNMP user for a set operation.
HARDWARE FACTORY DEFAULT
It is recommended that the device should have no cables and power supply connected. Press and
hold the RESET button (between COM1 and COM2). Then feed power to the device, with the button
held pressed for at least 5 seconds, until all LED’s on the lower row start blinking simultaneously.
Release the button and wait for a few seconds until the process is completed and the PWR LED is on.
This procedure restores all settings to their factory defaults, including the device’s IP address.
DHCP is on. Logs are not deleted.