Table 11: Parts List - With 4 Speed motor PSC 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03540

HEAT EXCHANGER ASSEMBLY

Heat exchanger only

2

J06L002

EXTRUDED JOINT 1/4 X 1/8 X 25'

3

B03570

FLOOR ASSEMBLY

4

B03561

INSIDE WIRE CHANEL

5

B03572

LOWER DIVIDER ASSEMBLY

Includes panel, 3 gaskets and baffle

6

B03335-02

INT. ELECTRICAL KIT BVSO

7

B03560

REAR BAFFLE

8

B03559-02

SIDE BAFFLE

9

B03571-02

PANEL ASSEMBLY, LEFT SIDE

Includes panel, insulation and baffle

10

B03589-02

SIDE PANEL INSULATION

11

B03562

SIDE FILTER RACK

12

B03563

REAR FILTER RACK

13

Z04F004

PAPER FILTER 20 X 20 X 1                    

14

B03576

BLOWER DOOR ASSEMBLY

Includes door, door handle and labels

15

Z99F050

RECESS HANDLE BLACK                     

16

B03577

REAR FILTER DOOR ASSEMBLY

17

F07O001

HEX FLANGE NUT 3/8-16NC LAITON          

18

B01697

FLUE OUTLET FLANGE, 5" DIA.                               

19

B01214

GASKET, SMOKE PIPE COVER                

20

B03578

TOP REAR PANEL ASSEMBLY

21

B03593

SOUND TRAP ASSEMBLY

Includes sound trap and insulation

22

B03558

TOP DIVIDER

23

B03564

OUTLET PROTECTOR

24

B03571-01

PANEL ASSEMBLY, RINGHT SIDE

Includes panel, insulation and baffle

25

B03589-01

SIDE PANEL INSULATION

26

B03559-01

SIDE BAFFLE

27

B03553

ELECTRICAL BOX SPACER

28

B03549

ELECTRICAL BOX

29

R02R008

HIGH LIMIT CTL205-30F, 7 in.

30

B03550

ELECTRICAL BOX COVER

Panel only

31

B03118-01

ELECTRICAL KIT BVSO EXT.                

32

B03596

BURNER WIRE CHANEL

33

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225-A

34

B03567

BAFFLE

35

B03587

CLEAN OUT ASSEMBLY

36

B03574

PROTECTION COVER ASSEMBLY

37

F07F011

HEX NUT 3/8-16NC ZINC                   

38

Z99F061

SIGHT GLASS FOR HEAT EXCHANGER

39

F06F015

ZINC WASHER 1 7/16" M20                 

40

B03554

WIRE CHANEL

41

L04I010

STRAIN REL. BUSHING

42

B03573

FRONT PANEL ASSEMBLY

Includes panel, insulation,observation door gasket

43

B03590

FRONT PANEL INSULATION

44

L07F003

ROCKER SWITCH SPST        

45

B03555

THERMO DISK PROTECTOR

46

B03465

ELECTRICAL KIT (BOARD)                    

47

R99G004

ELECTRONIC BOARD      

48

L01F009

TRANSFORMER  120-24Volts, 40VA          

49

B01024

CAPACITOR HOLDER

50

L01I001

CAPACITOR  5 MF 370V                  

51

B01664

ELECTRICAL KIT                          

52

B01888

MOTOR MOUNT ASSEMBLY

Include legs, band and fasteners

53

B01890-01

1/3 MOTOR AND SUPPORT ASS'Y

Includes motor and legs

54

B30473

BLOWER SUPPORT

55

B03720-04

BLOWER ASSEMBLY WITH LABEL

Housing, wheel and label only

56

B01405-03

REPLACEMENT BLOWER ASSEMBLY

Includes blower, motor and capacitor

57

B03428

GASKET, SMOKE OUTLET

 

B50082E

Содержание AMT098SD

Страница 1: ...Attention Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN Use the information in this manual for the installation servicing of the furnace...

Страница 2: ...JUSTMENTS HEATING MODE 4 SPEED MOTOR 7 TABLE 2 BLOWER SPEED ADJUSTMENTS A C MODE 4 SPEED MOTOR 7 TABLE 3 HEATING MODE 8 TABLE 4 AIR CONDITIONING MODE 8 TABLE 5 CFM ADJUSTMENT ALL MODES 8 TABLE 6 DELAY...

Страница 3: ...formation such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform...

Страница 4: ...so be located close to the centre of the air distribution system 2 1 1 INSTALLATION IN AN ENCLOSURE The unit can be installed in an enclosure such as a closet However 2 ventilation openings are requir...

Страница 5: ...nozzle sizes by working back from the desired flow rate at operating pressure and not the nozzle marking 2 5 2 AIR AND TURBULATOR SETTINGS Before starting the burner for the first time adjust the air...

Страница 6: ...k that the electrical outlet on the furnace designated to the BVSO is functional 1 Start up the burner 2 Remove the three pole plug from the BVSO outlet on the furnace 3 The burner must shut off immed...

Страница 7: ...led to the furnace casing Failure to properly seal ducts can result in death bodily injury and or property damage The ducting must be designed and installed according to approved methods local and nat...

Страница 8: ...24 VAC signal can also be supplied from the W and C terminals on the blower electronic board to activate a switching relay Also refer to the instructions supplied with the accessory 2 12 2 ELECTRONIC...

Страница 9: ...of the oil piping and pump Slowly close and tighten the bleed screw Once closed the flame will light up 3 3 2 PRESSURE ADJUSTMENT The oil pressure must be adjusted according to the Technical Specifica...

Страница 10: ...ed investigate for ductwork obstructions dirty or improper air filter improper firing caused by improper pump pressure or nozzle sizing 3 3 8 LIMIT CONTROL CHECK After operating the furnace for at lea...

Страница 11: ...bly cover 3 Remove the cover 4 Remove the two screws holding the control box to the heat transfer tube assembly Sliding the control box in the appropriate direction will unlock it from the heat transf...

Страница 12: ...vice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Am...

Страница 13: ...stion air adjustment turbulator damper 0 3 5 1 5 25 0 3 5 1 5 25 Minimum and Maximum pump pressure PSIG 125 to 180 135 to 170 125 to 180 135 to 170 AFUE From CSA B212 standard and Canadian regulation...

Страница 14: ...c 13 60 sec 38 3 min D 1 ON 2 ON All 13 30 sec 100 0 sec 100 2 min No adjustment required A C size PreRun On Delay CFM Level Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time All No Delay...

Страница 15: ...E XTE RNAL STATIC P RE SSURE WITH AIR FILTE R Table 10 Minimum clearances from combustible material LOCATION APP LICATION CLEARANCE S combustible ma terials RECOMMANDED ACCES S FO R SERVICE FURNACE 1...

Страница 16: ...16 Figure 7 Furnace Dimensions...

Страница 17: ...17 Figure 8 Wiring Diagram 4 Speed Motor PSC...

Страница 18: ...18 Figure 9 Wiring Diagram Variable Speed Motor ECM...

Страница 19: ...19 COMPONENTS AND REPLACEMENT PARTS...

Страница 20: ...20 Figure 10 Parts List With 4 Speed motor PSC B50082E...

Страница 21: ...B03589 01 SIDE PANEL INSULATION 26 B03559 01 SIDE BAFFLE 27 B03553 ELECTRICAL BOX SPACER 28 B03549 ELECTRICAL BOX 29 R02R008 HIGH LIMIT CTL205 30F 7 in 30 B03550 ELECTRICAL BOX COVER Panel only 31 B0...

Страница 22: ...22 Figure 11 Parts List With variable speed motor ECM B50083E...

Страница 23: ...03589 01 SIDE PANEL INSULATION 26 B03559 01 SIDE BAFFLE 27 B03553 ELECTRICAL BOX SPACER 28 B03534 ELECTRICAL BOX 29 R02R008 HIGH LIMIT CTL205 30F 7 in 30 B03550 ELECTRICAL BOX COVER Panel only 31 B031...

Страница 24: ...Ne pas alt rer votre unit ou ses contr les Appeler un technicien qualifi INSTALLATEUR TECHNICIEN Utiliser les renseignements dans ce manuel pour l installation et l entretien de l appareil et garder...

Страница 25: ...ALISATION OUVERTURE DE VENTILATION DANS LA PORTE DU PLACARD 4 FIGURE 2 BRANCHEMENT DU THERMOSTAT CHAUFFAGE ET CLIMATISATION UNIT AVEC MOTEUR 4 VITESSES 5 FIGURE 3 BRANCHEMENT DU THERMOSTAT CHAUFFAGE E...

Страница 26: ...onduit comment le changer une fois par ann e iv Le filtre air comment le changer v rifier mensuellement et nettoyer ou changer si n cessaire g Avant d appeler pour le service prendre en note les rense...

Страница 27: ...s doit tre utilis e 2 1 EMPLACEMENT MISE EN GARDE Risque d incendie ou d explosion L appareil doit tre install au niveau Ne jamais installer avec une inclinaison vers l avant Ne pas ranger ou utiliser...

Страница 28: ...d origine de l appareil de chauffage central utilisez seulement du fil de cuivre r sistant la m me temp rature que les fils d origine 2 3 INSTALLATION DU THERMOSTAT L installation d un thermostat de...

Страница 29: ...s avec le volet motoris Si cette fournaise ou d autres appareils ne sont pas ad quatement vacu s cela peut entra ner la mort ou des dommages corporels et ou mat riels Pour assurer un fonctionnement s...

Страница 30: ...ner une flamme malpropre des odeurs dans la maison le refoulement des appareils de combustion et peut entra ner des naus es l asphyxie et ou la mort des occupants L appareil de chauffage central n ces...

Страница 31: ...stribution d air conform ment aux m thodes approuv es et conforme aux codes locaux et nationaux Lorsque les conduits d alimentation d air transportent l air dans un autre espace que celui o la fournai...

Страница 32: ...C 10 10 ON ON D N A 0 Table 6 Ajustement des d lais en mode chauffage SW4 Delay D lai Position interrupteurs DIP 1 2 POSITION Puissance USGPH OFF OFF A 0 70 ON OFF B 0 55 OFF ON C 0 55 ON ON D ALL Po...

Страница 33: ...s et selon les sp cifications de ce manuel 8 Les d lais de d part et d arr t du ventilateur sont r gl s de fa on satisfaisante 9 Le thermostat de la pi ce est en mode chauffage et est r gl une temp ra...

Страница 34: ...age central installer le r gulateur de tirage barom trique fourni avec l appareil Pour que ce r gulateur fonctionne correctement monter les goupilles pins l horizontale et le devant du r gulateur la v...

Страница 35: ...e de l unit effectuer une v rification compl te de la combustion apr s chaque entretien annuel Ne pas tenter de r parer l unit ou les contr les de l appareil Appeler un technicien qualifi Avant d appe...

Страница 36: ...et fixer le bo tier de commande l aide des 2 vis qui avait t enlev es l tape 4 8 Remettre en place le couvercle de l ensemble avec les vis enlev es l tape 2 9 Remettre l alimentation lectrique 4 3 NE...

Страница 37: ...se du technicien de service R SULTAT DU TEST DE MISE EN MARCHE Gicleur Pression lb po 2 Ajustements du br leur Bande principale Bande fine Position de la t te CO2 Indice de fum e Bacharach Temp rature...

Страница 38: ...partir du standard CSA B212 et des lois canadiennes 86 1 85 0 86 1 85 0 AFUE partir du standard ASHRAE 103 et des lois am ricaines 85 7 85 0 85 7 85 0 Volts Hertz Phase Consommation Amp Amp minimum p...

Страница 39: ...19 60 sec 38 3 min C 1 OFF 2 ON 0 55 13 60 sec 13 60 sec 38 3 min D 1 ON 2 ON All 13 30 sec 100 0 sec 100 2 min Pas d ajustement requis Capacit climatisation PreRun D lai On Niveau PCM Temps ShortRun...

Страница 40: ...SSE AMT098 PRESS ION STATIQ UE EXTERNE AVE C FILTRE AIR Table 10 D gagement minimum mat riaux combustibles EMPLACEMENT APPLICATION D G AGEMENTS m at riaux combustibles ACC S RE COMMAND P OUR L ENTRETI...

Страница 41: ...18 Figure 7 Dimensions de la fournaise...

Страница 42: ...____________________________________________________________________________________ 19 Figure 8 Diagramme lectrique Moteur 4 vitesses PSC...

Страница 43: ...20 Figure 9 Diagramme lectrique Moteur vitesse variable ECM...

Страница 44: ...____________________________________________________________________________________ 21 COMPOSANTES ET PI CES DE REMPLACEMENT...

Страница 45: ...22 Figure 10 Liste de pi ces Avec moteur 4 vitesses PSC B50082E...

Страница 46: ...olation et d flecteur 25 B03589 01 ISOLATION PANNEAU DE COTE 26 B03559 01 DEFLECTEUR LATERAL 27 B03553 ESPACEUR DE BOITE ELECTRIQUE 28 B03549 BOITE ELECTRIQUE 29 R02R008 CONTR LE HAUTE LIMITE L205 30...

Страница 47: ...24 Figure 11 Liste de pi ces Avec moteur vitesse variable ECM B50083E...

Страница 48: ...rend panneau et isolation et d flecteur 25 B03589 01 ISOLATION PANNEAU DE COTE 26 B03559 01 DEFLECTEUR LATERAL 27 B03553 ESPACEUR DE BOITE ELECTRIQUE 28 B03534 BOITE ELECTRIQUE 29 R02R008 CONTR LE HAU...

Отзывы: