Table 9: Parts list, S

UPREME

Advantage PSC

#

Item

Description

Comments

1

B04343-04

Left side panel assembly

Left panel, items 3 and 1 included

2

B04344-02

Back panel assembly

3

B04343-02

Right side panel assembly

Right panel, items 7 and 1 included

4

B04302-01

Top front panel

5

L01J006

Breaker 60 A

6

K0371-A

Sequencer card assembly

Card and plastic pins

7

B04000-03

Modified 12 positions terminal

7

B04421

Components support

8

X50060

Cosmetic "Supreme A" 3 breaker

9

X50059

Cosmetic "Supreme A" 2 breaker

Supreme 15/18/20kw

10

X50058

Cosmetic "Supreme A" 1 breaker

Supreme 10kw

11

L01L006

Indicator light

12

L07F015

Switch SPDT

13

L01J001

Breaker 15 A

14

B04293

Electrical sequencer kit

Supreme 27/30kw

15

B04294

Electrical sequencer kit

Supreme 23/25kw

16

B04295

Electrical sequencer kit

Supreme 18/20kw

17

B04296

Electrical sequencer kit

Supreme 15kw

18

B04297

Electrical sequencer kit

Supreme 10kw

19

B04350-01

Top door

1-phase models

20

B04350-04

Top door

3-phase models

21

B04356-03

Blower assembly 1hp (120V-PSC)

Supreme 20/23/25/27/30 kw

22

B04356-01

Blower assembly 1/3hp (120V-PSC)

Supreme 10/15/18/20/23/25 kw

23

B04356-02

Blower assembly 1/3hp (240V-PSC)

Supreme 10/15/18/20/23/25 kw

24

B04356-04

Blower assembly 1hp (240V-PSC)

Supreme 20/23/25/27/30 kw

25

Z01I036

Blower 112-9R (1hp)

Supreme 20/23/25/27/30 kw

26

Z01I035

Blower 112-8R (1/3hp)

Suprême 10/15/18/20/23/25 kw

27

B01889

Motor support band and legs

28

L06K004

Motor 1hp (120V-PSC)

Supreme 20/23/25/27/30 kw

29

L06K005

Motor 1hp (240V-PSC)

Supreme 20/23/25/27/30 kw

30

L06G007

Motor 1/3hp (120V-PSC)

Supreme 10/15/18/20/23/25 kw

31

L06G015

Motor 1/3hp (240V-PSC)

Supreme 10/15/18/20/23/25 kw

32

B04287

Electrical blower kit

33

L01I001

Capacitor 5 uF

Supreme (120 PSC) 10 @ 25 kw

34

L01I003

Capacitor 10 uF

Supreme (240 PSC) 10 @ 25 kw

35

L01I005

Capacitor 15 uF

Supreme (240 or 120 PSC - 1 hp) 20 @ 30 kw

36

B01024

Capacitor support

37

B04303

Floor

38

B04309

Fan slide

39

B04304

Fan separator

40

B03299

Filter holder tip

41

B03298

Filter support outline

42

R02N028

Hi-limit 100+/-5.5C

43

B04308

Hi-limit deflector

44

L01H030

Relay DPST 22 VDC

45

B04369

Electrical power kit

46

L01H009

Relay 24 VAC

47

B04351-02

Element assembly

5kw

48

B04351-01

Element assembly

4kw

49

B04315-01

Element plate

50

L01F010

Transformer 208/240/24

51

L99F007

Terminal bloc 600V/175A (1423570)

3 positions

52

L99F008

Terminal bloc 600V/175A (1422570)

2 positions (27 & 30 kW only)

53

B04359

Blower grill

54

B04306

Deflector

Accessoires

DFB-SUP

Base for downflow

(ref: B03310-03)

K03081

HP/AC interface kit

BRB-SUP

Bottom return base

21

Содержание ADVANTAGE SUPXX-A120D12

Страница 1: ...0 INSTALLER SERVICE TECHNICIAN Attention Do not tamper with the unit or its controls Call a qualified service technician USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FU...

Страница 2: ...ATION 9 5 FURNACE INFORMATION 9 6 TECHNICAL SPECIFICATIONS 10 7 NOTES 22 List of figures Figure 1 Upflow Configuration 4 Figure 2 Downflow Configuration 4 Figure 3 Horizontal Configuration 4 Figure 4...

Страница 3: ...d for use by a qualified technician familiar with safety procedures and who is equipped with the proper tools and test instruments Failure to carefully read and follow all instructions in this manual...

Страница 4: ...8 VAC power supply to the control panel thermostat hook up as shown on the wiring diagram 2 1 POSITIONING THE FURNACE WARNING FIRE AND EXPLOSION HAZARD The furnace must be installed in a level positio...

Страница 5: ...and or property damage 2 4 ELECTRICAL SYSTEM The SUPREME furnace is completely pre wired and all field wiring must be connected to the terminal blocks on the unit It requires 2 service wires of 240 20...

Страница 6: ...t be changed to the 208V position 2 5 INSTALLATION OF THE THERMOSTAT A thermostat must be installed to control the temperature of the area to be heated Follow the instructions supplied with the thermo...

Страница 7: ...nd return air connectors to avoid the transmission of vibration To make the unit run even quieter the installer should 1 Use two elbows between each outlet and the supply and return air plenum 2 Cover...

Страница 8: ...structions provided with the thermostat or the Fossil Fuel kit for the proper wiring of the furnace and the heat pump The simultaneous operation of the electric elements and the heat pump will cause o...

Страница 9: ...on of the average airflow To do that the following formula should be used Liter s 0 82 amps volts Diff temperature C CFM 3 1 amps volts Diff temperature F Tables 5 and 6 show estimated airflows for va...

Страница 10: ...rmostat higher than room temperature If the unit does not start up cut the power and call a qualified service technician When calling for service or ordering a replacement part specify the model and s...

Страница 11: ...5 9 9 11 5 9 9 11 5 9 9 11 5 9 9 11 5 9 9 Heating Elements Consumption 240V 208V Amp 41 4 35 9 62 1 53 8 75 8 65 7 82 8 71 8 96 5 83 6 103 5 89 7 82 8 71 8 96 5 83 6 103 5 89 7 113 6 98 5 124 3 107 7...

Страница 12: ...1 5 9 5 1 5 9 5 1 5 9 5 1 Heating Elements Consumption 240V 208V Amp 41 4 35 9 62 1 53 8 75 8 65 7 82 8 71 8 96 5 83 6 103 5 89 7 82 8 71 8 96 5 83 6 103 5 89 7 113 6 98 5 124 3 107 7 Total Consumpti...

Страница 13: ...or Consumption 240V 208V Amp Max 2 6 2 3 5 9 5 1 Heating Elements Consumption 240V 208V Amp 57 8 50 1 72 2 62 6 Total Consumption 240V 208V Amp 60 4 52 3 78 1 67 7 Ampacity 240V 208V Amp 76 66 93 81 S...

Страница 14: ...est 5CFM Data taken with air filter in place Table 6 Airflow CFM SUPREME with 1HP motor Furnace equipped with a 1HP 120 blower motor Blower External static pressure inche of W C Speed 0 2 0 3 0 4 0 5...

Страница 15: ...559mm 22 25mm 1 SUPPLY ALIMENTATION 508mm x 508mm 20 x 20 REVISIONS REV DESCRIPTION A C DATE PAR Figure 12 Advantage Dimensionsi 451mm 17 3 4 451mm 17 3 4 RETURN 483mm x 483mm 19 x 19 RETOUR Identical...

Страница 16: ...Figure 13 lectrical diagram Supreme Comfort PSC 15...

Страница 17: ...Figure 14 lectrical diagram Supreme Advantage PSC 16...

Страница 18: ...Figure 15 lectrical diagram Supreme Advantage PSC 3 phases ELECTRICAL DIAGRAM DIAGRAMME L CTRIQUE ADVANTAGE AVANTAGE PSC 3 PHASES 17...

Страница 19: ...20 23 24 25 28 27 B50147 rev F 7 8 9 10 11 12 13 5 6 REV DESCRIPTION A C DATE PAR B Changement Disjoncteur 22314 2015 05 15 F H C Ajoute support de filtre Change item 1 22388 2015 07 01 F H D TIQUETT...

Страница 20: ...10 15 18 20 kW 20 B01889 Motor support band and legs 21 L06K004 Motor 1hp 120v PSC Supreme 20 kW 22 L06K005 Motor 1hp 240v PSC Supreme 20 kW 23 L06G007 Motor 1 3hp 120v PSC Supreme 10 15 18 20 kW 24...

Страница 21: ...rev F 9 12 13 14 8 6 7 15 16 17 18 19 10 11 REV DESCRIPTION A C DATE PAR B Changement disjoncteur pour CQC 22326 2015 05 19 F H C Ajoute support de filtre Change item 1 22389 2015 07 01 F H D TIQUETT...

Страница 22: ...18 20 23 25 kw 24 B04356 04 Blower assembly 1hp 240V PSC Supreme 20 23 25 27 30 kw 25 Z01I036 Blower 112 9R 1hp Supreme 20 23 25 27 30 kw 26 Z01I035 Blower 112 8R 1 3hp Supr me 10 15 18 20 23 25 kw 27...

Страница 23: ...7 NOTES 22...

Страница 24: ...23...

Отзывы: