TROUBLESHOOTING TIPS
The following are a few of the most common questions the Customer Support group answers.
Symptom:
Gates do not move on start-up,
Solution:
Blocked sensor. Use LCD display I/O diagnostic on Page 15 to determine which sensor is
problematic.
Symptom:
Gates misaligned at center.
Solution:
If mounting is square and plumb, ensure Plastic Bumpers are still on Top Cover, Page 16.
Symptom:
Gates vibrate during operation, or overtravel when stopping.
Solution:
Tighten Barrier mounting bolts, Page 10.
Symptom:
Multiple users card in, only first user allowed to pass.
Solution:
The Access Control System is holding the Valid User (Entry or Exit) Input for subsequent users.
The Access Control System needs to be adjusted to provide a shorter cycle time (preferably less
than half a second contact closure) in order to provide a discrete input cycle to the ES9000 for
each valid card read. Because many Access Control Systems are built to control door locks,
their default setting is five seconds, and the system simply holds the lock for each subsequent
user rather than providing a unique input cycle (Open/Close/Open) for each valid user.