FINAL TESTING PROCEDURE
With all wiring and setup completed, turn on power switch. Barriers will slowly move toward the Public
side until they both come in contact with the Plastic Bumper on the Top Cover. They will then swing
180° toward the Secure side to verify a clear path. They will then return to the center position and be
ready for operation. Follow the table below to test basic functions. Apply the designated input, then
check for the indicated responses. Once finished, if you haven’t already, install all covers as indicated
on Page 11.
INPUTS
OUTPUTS
BARRIER
POSITION
ALARM
VALID
ENTRY
VALID
EXIT
BYPASS AUDIBLE
ENTRY CARD
O
Entry direction for duration
of Card Access Time
EXIT CARD
O
Exit direction for duration of
Card Access Time
INVALID CARD
O
Centered/Armed
RESET/BYPASS
O
Entry direction
ENTRY CLOSED
Center if no other activity
EXIT CLOSED
Center if no other activity
FREE EXIT
(EXIT HELD 20s)
Exit direction when “D”
Sensor is broken by user
EMERGENCY
O
Exit direction
BARRIER AND SENSOR STATES
FORCED
BARRIER
& PASSAGE
O
O
BARRIERS WILL
PROVIDE RESISTANCE
AGAINST ATTEMPTS TO
FORCE PASSAGE
NO
PASSAGE
TAILGATE
O
O