PRIMARY ELECTRONICS DETAIL
Inputs from Access Control System
Entry Valid
Card Read
1-2
Dry contact closure indicating valid
Entry card read
(Momentary Closure of .3 to .5
second recommended)
Exit Valid
Card Read
3-4
Dry contact closure indicating valid
Exit card read
(Momentary Closure of .3 to .5
second recommended)
Hold input for more than 20s for
Free Exit
Invalid Card
5-6
Dry contact closure when an invalid
card has been presented.
Inputs for Remote Control
Reset/Bypass
7-8
Dry contact closure to reset alarms
or to bypass the lane, stow the
barriers and allow unrestricted
traffic flow.
Entry Closed
9-10
Dry contact closure disables Entry
mode.
Exit Closed
11-12
Dry contact closure disables Exit
mode.
Emergency
13-14
Dry contact closure, moves
Barriers to Exit, activates alarm
graphics, and alarm relay output.
Reserved
15-16
Reserved for future use.
Reserved
17-18
Reserved for future use
Outputs for Remote Monitoring
Alarm
1-2
Indicates that unit is in Alarm
Mode.
Alarm
3-4
Indicates that unit is in Alarm
Mode.
Valid Exit
5-6
Indicates that an Exit passage was
completed. Closes for .3 sec when
triggered.
Valid Entry
7-8
Indicates that an Entry passage
was completed. Closes for .3 sec
when triggered.
Bypass
9-10
Indicates when unit is in Bypass
Mode.
Inputs
Outputs
Lane
Data
Lane
Power
24VDC
Power
N/O - N/C
Jumpers
PLC
Motor Driver
Power
Switch
Data
Status
LED
WARNING:
Multiple lanes sharing a common Input Source (i.e. Fire Alarm) must be isolated