SPECIFICATIONS
Power:
24-26 VDC @ 4 Amps per walkway
Wiring:
Power-
Less than 50 feet;
-14 Gauge
50 to 100 feet;
-12 Gauge
(See Power Wire Gauge calculator on page 24 for detail)
Signal-
50 to 200 feet;
-22 Gauge
Inputs:
N/O Dry Contact for
- Valid Entry Card (from Access Cntrl)
N/O Dry Contact for
- Valid Exit Card
(from Access Cntrl)
N/O Dry Contact for
- Invalid Card
(from Access Cntrl)
N/O Dry Contact for
- Bypass/Reset/Override
N/O Dry Contact for
- Entry or Exit Closed
N/O Dry Contact for
- Emergency
(Fire Alarm)
Outputs:
Output relays are rated for 1A @ 5-30 VDC
Output relays may optionally be N/C, see Page 14
N/O Dry Contact for
- Alarm (2X)
N/O Dry Contact for
- Valid Entry
N/O Dry Contact for
- Valid Exit
N/O Dry Contact for
- Bypass
Audible Alarm:
80db at 3 feet
Timing Adjustments:
Card Access
(3-15 Seconds timeout if no passage)
Alarm Auto-Reset
(3-15 Seconds timeout for Alarm sounder)
Dimensions:
9"W X 38"H X 49"L
Walkway Spacing:
Standard / A.D.A.
- 36” between pedestals
Custom Lane Widths may differ from Standard
Mounting:
1/4” Steel base with eight .75” x 1.25” Slotted Mounting Holes
and three 2.25” Dia Cable Access Holes per pedestal
Interconnect Cables:
Power:
20’
Data:
20’
WARNING:
Multiple lanes shar-
ing a common Input Source must
be isolated through a unique relay
contact for each lane input. Wiring
common inputs in a daisy-chain
(parallel) can cause damage to
electronics.