Periodic inspection and maintenance
GAW-185ES2
- 34 -
(7) Connection and check of battery cables
Connect battery cables in correct polarity. If connection is made in incorrect polarity (reversing of +
and -), electric components will be damaged, even if such an error occurred only for a short length
of time.
[Caution]
: Connect battery cables in the state where the starter switch key is removed.
Applying small amount of grease to battery terminals will prevent corrosion to terminals.
Furthermore, firmly connect cables to terminals. If connection is insufficient, malfunction may arise
due to faulty contact, and troubles may result.
Содержание GAW-185ES2
Страница 22: ...Periodic inspection and maintenance GAW 185ES2 36 Push Push...
Страница 45: ...Conveyance and installation GAW 185ES2 59 8 Servicing data 8 1 External dimensions and appearance drawing...
Страница 47: ...Conveyance and installation GAW 185ES2 61 8 3 Generator wiring diagram...
Страница 48: ...Conveyance and installation GAW 185ES2 62 8 4 Engine wiring diagram...