![Denyo DCA-150ESK Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/denyo/dca-150esk/dca-150esk_instruction-manual_2485062016.webp)
With " AUTO " selected,
indication is automatically changed every
three (3) seconds.
- 1 - Engine Speed
Revolutions per minute is indicated.
XSOOmin -1 is indicated at 50Hz and 1800 min -1 is indicated at 60Hz.
- 2 - Engine Oil Pressure
2 to б X 100 kPa ( 2 to 6 kg / cm1 ) should be indicated at normal
engine operation.
Higher value would be indicated in cold condition
immediately after engine starts.
Conduct a wanning - up operation
until it indicates normal value.
- 3 - Run Hours
That indicated total running hours.
- 4 - Battery Charging Voltage
That should indicate more than 26V at engine running.
- 5 - Engine Coolant Temperature
That should indicate a temperature between 75 to 90 °C at engine running.
Note ; If that would indicate higher temperature,
disconnect all loads,
decrease the speed for cool - down operation,
and wait until the
temperature comes down to normal value.
- 6 - Automatic Indication Change
Each of the above - started indications from the - 1 - to - 5 - changes by turns
every 3 seconds.
(2)
Fuel Level Indicator
That Indicates a fuel level in the fuel tank.
Green lamps will turn on with full tank.
As the fuel level drops,
the numbers of the turn - on lamps decrease and at the
sametime the color of lamps changes from green to red.
Replenish the tank when there becomes only one lamp turned on.
The table below shows the relation between numbers of turn - on lamps and feul level.
- 15 -