34
be entered to the cursor
tate
) Numeric data transmission format
Select the "Inboard keys" or "TEN keys" on the connected keyboard. (Default: Inboard keys)
(4) Binary conversion
Select the conversion type to be applied to data read, from the following:
- "No conversion" (ASCII) (default) : Outputs 00h to 7Fh data in ASCII format bytewise. Selecting this parameter
does not output 80h to FFh data.
- "Binary conversion"
: Converts 00h to FFh data to binary format and outputs it bytewise.
- "Kanji conversion"
: Converts 00h to FFh data to Shift-JIS format and outputs it, two bytes at a
time. If there is any data to which this Kanji conversion cannot apply, it
converts such data to binary format and outputs it bytewise instead.
Note that some applications may fail to output converted data as it is displayed.
(Example) If the code data is “Kanji”:
DATA:Kanji
Shift JIS:8ABF, 8E9A
Binary Data Conversion
Output Data
Remarks
9.2
USB Keyboard Interface
The USB keyboard interface requires no dedicated device driver. Data read by the scanner can
position in your application.
The USB keyboard interface operates in conformity with the following:
- Universal Serial Bus (USB) Device Class Definition for Human Interface Devices (HID) Version 1.11
- Universal Serial Bus (USB) HID Usage Tables Version 1.11 keyboard
(1) CAPS Lock s
Select the CAPS Lock ON or OFF to match the state of the connected keyboard. (Default: CAPS Lock OFF)
(2) Keyboard type
Select the type of the connected keyboard. (Default: Type 106, Japanese)
(3
None
Not output
Only indicates that scanning is complete.
Binary conversion
8Ah BFh 8Eh 9Ah assigned characters
Outputs 1 byte at a time in binary data.
Kanji conversion
"Kanji"
Converted to Kanji and output.
(Note 1)
(Note 1) Some applications cannot output data correctly on the display.
(5) Data transmission interval
Select the data transmission interval to be applied when the scanner sends data read to the host computer. There are
seven choices from 3 ms to 100 ms (default: 10 ms).
Содержание QK30-U
Страница 1: ...2D Code Scanner Fixed type QK30 U User s Manual...
Страница 22: ...11...
Страница 86: ...75 USB interface to the host USB COM interface USB keyboard default interface...
Страница 89: ...78 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...
Страница 90: ...79 Header USB keyboard interface...
Страница 91: ...80 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...
Страница 99: ...88 Speaker control Other settings Disable Enable default Indicator LEDs Disable Enable default...
Страница 113: ...2D Code Scanner Fixed type QK30 U User s Manual First Edition May 2014 DENSO WAVE INCORPORATED...
Страница 114: ...DENSO WAVE INCORPORATED Chita gun Aichi 470 2297 Japan http www denso wave com 1 Yoshiike Kusagi Agui cho...