9
Chapter 6 Scanning Control
6.1 Software
Control
You can control the scanner by sending scanning control commands from the host computer via USB-COM interface.
(For details about control commands, refer to Appendix 2.)
Commands
Description
R
Ready-to-scan command
Upon receipt of one of these commands, the scanner lights the illumination LEDs and
becomes ready to scan.
Z
Standby command
Upon receipt of one of these commands, the scanner turns off the illumination LEDs and
switches to standby.
Each of these commands should be enclosed with a header and terminator for transmission according to the
communications conditions of the scanner.
6.2
Automatic detection of labels
Bringing a code label within the scan range of the scanning window turns on the illumination LEDs and starts the
scanner reading the code.
The illumination LEDs come on when you bring a code label within the designated range or move a code label within
the same range. These LEDs go off when a code label is moved away from the range or stays within the range without
move for approx. 3 seconds.
The scanner offers a choice of three code response levels. Switch to a higher code response level if the illumination
LEDs will not come on when a code is brought into the range, for example. The code response level can be specified
with the configuration software (ScannerSetting_2D).
Note:
Even if you do not bring a code label within the scan range, the illumination LEDs may come on when the
ambient level of light changes or any shadows move within the scan range.
Note:
To enable the scanner to work properly in auto sensing mode, an ambient illuminance of at least 30 lx is
required.
Содержание QK30-U
Страница 1: ...2D Code Scanner Fixed type QK30 U User s Manual...
Страница 22: ...11...
Страница 86: ...75 USB interface to the host USB COM interface USB keyboard default interface...
Страница 89: ...78 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...
Страница 90: ...79 Header USB keyboard interface...
Страница 91: ...80 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...
Страница 99: ...88 Speaker control Other settings Disable Enable default Indicator LEDs Disable Enable default...
Страница 113: ...2D Code Scanner Fixed type QK30 U User s Manual First Edition May 2014 DENSO WAVE INCORPORATED...
Страница 114: ...DENSO WAVE INCORPORATED Chita gun Aichi 470 2297 Japan http www denso wave com 1 Yoshiike Kusagi Agui cho...