5. Initial operation of control unit Control 44 / Control 45
Attention!
The control units Control 44 / Control 45 feature a static
current circuit. If this static current circuit is interrupted, power
operation of the door is no longer possible. Elements within
this static current circuit are e.g. the cable slack switch, the wicket door switch
and cable safety switch. If these elements are not available, insert enclosed
short-circuit plug into socket X30.
5.2
Connection control unit — door leaf
Attention!
If you want to put a door system with
closing edge safety
devic
e into operation, please pass on according to wiring
diagram mentionned on page 29 insted of wiring diragram
mentionned below. For following operational check the optosensor
(transmitter and receiver) may not be connected.
Connection of cable slack device
(only Dynamic 121 - 128)
• Connect system cable to socket
X30