English / Page 12
Legend:
Switches (system plugs):
S5
Wicket door switch
S6
Cable slack switch
S7
Night lock
Switches
(terminal screw connections):
S5a
*
Wicket door switch
S6a
*
Cable slack switch
S6b
*
Cable safety device
Plug connections:
X30
Closing edge safety device
(in control unit)
X71A
Wicket door contact
X71B
Cable slack switch
X71C
Night lock
X73
Connection cable
X74
♦
Optosensor transmitter
Terminal blocks:
X2c
Static current circuit
(in control unit)
X7C
Coiled cable
X7H
Static current circuit
X7L
Cable slack switch
* If connected, the short-circuit bridge
must be removed
♦
If available
5. Initial operation of control unit Control 44 / Control 45
• Insert the control unit mains plug into a site electric socket in accordance with
CEE standard 16 A.
• Check that the power supply at this socket corresponds to the voltage indicated
on the rating plate of the control unit and also that its protection category
complies with the local regulations.
• If the control unit is to be connected directly to the mains, a mains isolator
switch will have to be installed.
Fig. 9: Wiring diagram
Advice:
For Control 44:
Make sure that the field rotates clockwise.