Chapter 5 Parameters
|
VFD-M-D Series
5-46
Revision Jan. 2007, MDE2, SW V1.05
Group 4: Door Close Parameters
4 - 00
Door Close High Speed 1
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 30.00
4 - 01
Door Close Final Speed Start
Unit: 0.1
Settings
0.0~100.0% (0.0%: close complete, 100.0%:
open complete)
Factory Setting: 4.0
4 - 02
Door Close Final Speed
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 5.00
4 - 03
Door Close Holding Speed Start
Unit: 0.1
Settings
0.0~100.0% (0.0%: close complete, 100.0%:
open complete)
Factory Setting: 1.0
4 - 04
Door Close Holding Speed
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 2.00
4 - 05
Door Close Acceleration Time 1
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 2.0
4 - 06
Door Close Deceleration Time 1
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 2.0
4 - 07
Door Close High Speed 2
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 20.00
4 - 08
Door Close Acceleration Time 2
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 10.0
4 - 09
Door Close Deceleration Time 2
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 10.0
Pr.4-00 to Pr.4-09 can be used only when Pr.00-09 is set to 00 Distance control mode 1 or 01
Distance control mode 2.
Please adjust by following diagram to meet your application.
Содержание VFD-M-D series
Страница 1: ...M D...
Страница 2: ......
Страница 3: ...M D...
Страница 9: ...C 2 General Precaution C 4 C 3 How to Choose a Suitable Motor C 5...
Страница 31: ...Chapter 3 Start Up VFD M D Series 3 4 Revision Jan 2007 MDE2 SW V1 05 This page intentionally left blank...
Страница 121: ...Chapter 5 Parameters VFD M D Series 5 88 Revision Jan 2007 MDE2 SW V1 05 This page intentionally left blank...
Страница 155: ...Appendix B Accessories VFD M D Series B 12 Revision 10 2005 BE13 This page intentionally left blank...