Chapter 5 Parameters
|
VFD-M-D Series
Revision Jan. 2007, MDE2, SW V1.05
5-39
Group 3: Door Open Parameters
3 - 00
Door Open Coupling speed
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 8.40
3 - 01
Door Open High Speed Start
Unit: 1
Settings
00~65535 (pulse number)
Factory Setting: 300
3 - 02
Door Open High Speed 1
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 42.00
3 - 03
Door Open Final Speed Start
Unit: 0.01
Settings
0.0~100.0% (0.0%: close complete, 100.0%:
open complete)
Factory Setting: 95.0
3 - 04
Door Open Final Speed
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 5.00
3 - 05
Door Open Holding Speed Start
Unit: 0.1
Settings
0.0~100.0% (0.0%: close complete, 100.0%:
open complete)
Factory Setting: 99.0
3 - 06
Door Open Holding Speed
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 2.00
3 - 07
Door Open Acceleration Time 1
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 2.0
3 - 08
Door Open Deceleration Time 1
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 2.0
3 - 09
Door Open High Speed 2
Unit: 0.01
Settings
0.00~400.0Hz
Factory Setting: 30.00
3 - 10
Door Open Acceleration Time 2
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 10.0
3 - 11
Door Open Deceleration Time 2
Unit: 0.1
Settings
0.1~3600sec
Factory Setting: 10.0
The unit of Pr.3-01 is pulse number. It should be less than Pr.3-03 after converting to %.
Please adjust by following diagram to meet your application.
Содержание VFD-M-D series
Страница 1: ...M D...
Страница 2: ......
Страница 3: ...M D...
Страница 9: ...C 2 General Precaution C 4 C 3 How to Choose a Suitable Motor C 5...
Страница 31: ...Chapter 3 Start Up VFD M D Series 3 4 Revision Jan 2007 MDE2 SW V1 05 This page intentionally left blank...
Страница 121: ...Chapter 5 Parameters VFD M D Series 5 88 Revision Jan 2007 MDE2 SW V1 05 This page intentionally left blank...
Страница 155: ...Appendix B Accessories VFD M D Series B 12 Revision 10 2005 BE13 This page intentionally left blank...