![Delta SOLIVIA 10 EU T4 TL Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/delta/solivia-10-eu-t4-tl/solivia-10-eu-t4-tl_operation-and-installation-manual_2472310056.webp)
56
Wiring the Inverter
Maximum rating of input power:
Type of limit
10 TL
15 TL
20 TL
30 TL
Total input power
11 kW
16.5 kW
22 kW
30 kW
Input 1 & Input 2
7.3 kW
11 kW
14.7 kW
20.1 kW
Cable size:
Current rating
Wire size
DC 34 A
5-6 mm
2
/ 10 AWG
DC wiring polarity is divided into positive and negative, which is shown in Figure 6-9. The connec-
tion should be consistent with the indicated polarity marked on the inverter.
Figure 6.9.: DC Wiring Illustration
6.3.1 asymmetrical Loading for 10 TL, 15 TL, 20 TL, and 30 TL
The inverters operate using two separate MPP trackers that can handle both symmetrical and
asymmetrical loads to allow for optimum adjustment. This allows for the requirements of complex
PV system designs to be fulfilled. For example: east/west-facing roof (symmetrical load) or a
south facing roof such as a dormer (asymmetrical load).
See the following figures for explanation of how symmetrical and asymmetrical loading are
handled:
Содержание SOLIVIA 10 EU T4 TL
Страница 2: ......
Страница 99: ...99 EN Maintenance 2 3 4 1 Figure 8 1 Steps of removing the fan bracket from the inverter ...
Страница 101: ...101 EN Maintenance Figure 8 3 Removing the Vent Covers for Cleaning ...
Страница 117: ...117 EN Technical data 12 3 Earthing Systems for 10 TL 15 TL 20 TL 30 TL Figure 12 1 Earthing Systems ...
Страница 119: ...119 13 Certificates ...
Страница 121: ......