55
EN
Wiring the Inverter
➀
➁
➂
➃
DC input panel for the 10
TL, 15 TL, and 20 TL has 4
DC inputs. The 30 TL DC
input interface shown
below, provides 6 DC
inputs.
SOLIVIA 30 EUT4TL
Figure 6.8.: Input/Output Interface
no.
Designation
Description
➀
AC connector
400 V
AC
for 10 / 15 / 20 TL ; 500 V
AC
for 30 TL
➁
Communication
2 × RS485, 1 × EPO, 2 × Dry contact
➂
DC connector
4 Strings (10 TL / 15 TL / 20 TL), 6 Strings (30 TL)
➃
Fans
4 Fans (10 TL model with only one fan)
nOTE
The fans shown are without the required protective screen for illustrative
purposes
CaUTIOn
Machine and equipment damage may occur.
► The connection number of PV ARRAY, open circuit voltage and power
of String_1 and String _2 must be coherent.
► The connection number of PV ARRAY, open circuit voltage and power
of String _3 and String _4 must be coherent.
► The maximum open circuit voltage of PV Array must not exceed 1000 V.
► The range of V
mpp
of Input DC1 and Input DC2 shall be 350~800 V
DC
.
► The device installed between PV array and inverter must meet the rat-
ing of voltage <1000 V
DC
and < short current.
► The input power connected to the inverter must not exceed the maxi-
mum rating of input power as shown in the table below.
Содержание SOLIVIA 10 EU T4 TL
Страница 2: ......
Страница 99: ...99 EN Maintenance 2 3 4 1 Figure 8 1 Steps of removing the fan bracket from the inverter ...
Страница 101: ...101 EN Maintenance Figure 8 3 Removing the Vent Covers for Cleaning ...
Страница 117: ...117 EN Technical data 12 3 Earthing Systems for 10 TL 15 TL 20 TL 30 TL Figure 12 1 Earthing Systems ...
Страница 119: ...119 13 Certificates ...
Страница 121: ......