Appendix A: Wiring
deltamotion.com
49
D24: Discrete Inputs
To turn on a discrete input, apply a voltage of the correct level. The
polarity is unimportant for inputs 0-19, and is important for 20-23.
Inputs 0-19
The inputs 0-19 are polarity-independent and can be sinking or
sourcing. Inputs 0-19 are divided in three groups: 0-7, 8-16, 17-21.
Each group shares a common, so all inputs in a group must be wired
the same.
Used with a sourcing output
Used with a sinking output
RMC Module
InCmn
In
PLC
+VCC (12-24 VDC)
Douts+
DOut -
PLC
RMC Module
In
In
InCmn
Power
Output
Output
In
Inputs 20-23
Each input is individually isolated and has
Din+
,
Din +5V
, and
Din–
connections. Use only
Din+
or
Din+5V
, not both.
D24
Din+
DIn +5V
DIn -
n/c
D24
Din+
DIn +5V
DIn -
n/c
Apply 12-24 VDC
to turn on
Apply 5 VDC to
turn on
Example:
Inputs 0-19
Inputs 20-23
Signal Levels
12-24 VDC
5-24 VDC
Max Current Draw
3 mA
7 mA
PLC
D24
Din+
DIn +5V
DIn -
n/c
Power
Output (24VDC)