RMC200 Startup Guide
20
Delta Computer Systems, Inc.
SSI Feedback
1.
In the
Axis Parameters
pane, on the
Setup
tab, set the
Feedback
Type
to
SSI
.
2.
Set the following parameters:
•
SSI Format
•
SSI Data bits
(e.g. 24)
•
Linear/Rotary
Choose
Format
and
Data Bits
per the SSI device data sheet.
For linear transducers, choose
Linear
. For rotary encoders, choose
Rotary
if the axis on your machine can rotate continuously and
the positions wrap around, or
Linear
if it has a limited travel range
and the encoder will not cross the zero counts point.
Note:
For help on a parameter, click the cell and press F1.
3.
Click the
Download
button to apply the changes to the RMC.
4.
Continue to the
Verify Feedback
section on page 22.
Start/Stop or PWM (Magnetostrictive) Feedback
1.
In the
Axis Parameters
, on the
Setup
tab, set the
Feedback Type
to
MDT
.
2.
Set
MDT Type
to the type of
magnetostrictive transducer
you have.
This information is available
from your transducer
datasheet.
3.
Click the
Download
button to apply the changes to the RMC.
4.
Continue to the
Verify Feedback
section on page 22.
Содержание RMC200
Страница 1: ...RMC200 MOTION CONTROLLER STARTUP GUIDE With wiring diagrams Connect Control Optimize ...
Страница 56: ...RMC200 Startup Guide 52 Delta Computer Systems Inc B7 B11 B15 ...
Страница 58: ...RMC200 Startup Guide 54 Delta Computer Systems Inc Notes ...
Страница 59: ...Appendix C Agency Compliance deltamotion com 55 Notes ...
Страница 60: ...RMC200 Startup Guide 56 Delta Computer Systems Inc The RMC Family of Motion Control Connect Control Optimize ...