Step 5: Connect RMC to PC
deltamotion.com
7
Step 5: Connect RMC to PC
USB Cable
Connect an A to B USB cable to the PC and
to the RMC200
USB
port.
This type of USB cable is typically used for
PC peripherals such as printers, and is
available at any store that sells electronics.
Or, use Ethernet Cable
Connect an Ethernet cable to the RMC200 and the PC
or Ethernet switch. The RMC200 supports both
straight through and crossover cables.
Setting the IP Address
The IP address need not be set before connecting via Ethernet. If the
PC is on the same physical Ethernet network as the RMC, RMCTools
can detect the RMC even if the IP address is not set.
The RMC’s IP address and subnet mask can be set via RMCTools while
connecting via Ethernet. See the next step
Start a New Project
for
details.
Or, set the IP address and subnet mask via the CPU display screen:
1.
Using the
Menu
, arrow
and
Enter
buttons, browse to:
Ethernet
Change IP Address
Set manually
2.
Using the arrow
buttons, set the IP address.
3.
Press
Enter
for Next and set the subnet mask.
4.
Press
Enter
for Next and use the arrow
and Enter
buttons to choose whether to use a default gateway. Set it if so
desired.
Содержание RMC200
Страница 1: ...RMC200 MOTION CONTROLLER STARTUP GUIDE With wiring diagrams Connect Control Optimize ...
Страница 56: ...RMC200 Startup Guide 52 Delta Computer Systems Inc B7 B11 B15 ...
Страница 58: ...RMC200 Startup Guide 54 Delta Computer Systems Inc Notes ...
Страница 59: ...Appendix C Agency Compliance deltamotion com 55 Notes ...
Страница 60: ...RMC200 Startup Guide 56 Delta Computer Systems Inc The RMC Family of Motion Control Connect Control Optimize ...