C h a p t e r 9 E t h e r n e t S p e c i f i c a t i o n a n d O p e r a t i o n
9 - 3 5
9_
In the New Module dialog box, click the
Connection
tab to modify the
Requested Packet Interval
and
Input Type
settings. The RPI uses the I/O connection to a Scanner to exchange data at regular intervals, and the units are
micro-seconds. For
Input Type
select either
Unicast
or
Multicast
. The Input Type selections may vary for different
products.
Click
OK
to create the adapter. The new Delta Adapter appears in the Controller Organizer tree.
9.6.4.3 Editing Corresponding Addresses for DVP-ES3
Refer to section 9.7.5 Assembly Object for defaults of mapping address. Refer to section 9.6.4.5 on how to open
Program TAG and modify the contents of TAG:C to edit the mapping addresses. Refer to section 9.7.5 Assembly Object
for details on TAG:C.