C h a p t e r 8 H a r d w a r e C o n f i g u r a t i o n
8 - 11
8_
Position Control Parameter
The parameters on
Position Control Parameter
table set to specify input points as the positive and
negative limits of axis 1~ axis 4 channels. 12 limit points can be set at most. Axis No. 1~4 can also be set
as Z phase triggers, home function finish points and clear output selects or positive/negative limited
position.
Axis1 (Y0/Y1) Positive/negative Limited Select~ Axis4 (Y6/Y7) Positive/negative Limited
Select: select the rising or falling edge trigger and X input point on the drop-down list.
Axis1 (Y0/Y1) Z Phase Trigger ~ Axis4 (Y6/Y7) Z Phase Trigger:
Select the rising or falling edge trigger and X input point on the drop-down list.
Axis1 (Y0/Y1) Home Function Finish and Clear Output Select ~ Axis4 (Y6/Y7) Home Function Finish
and Clear Output Select: select the rising or falling edge trigger and X input point on the drop-down list.
Axis1 (Y0/Y1) Positive/negative Limited Position ~ Axis4 (Y6/Y7) Positive/negative Limited Position: set
up the number of pulses as the positive or negative limited position in axis 1~4; setting range is
-2147483647
~
2147483647.