LYTE II DIN Rail Power Supply 

DRL-240W series / DRL-

V240W1EN

 

TECHNICAL DATASHEET

 

 

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (March 2022, Rev. 04) 

 

2

 

Specifications 

 

Model Number 

DRL-12V240W1EN 

DRL-24V240W1EN

 

DRL-48V240W1EN 

 

Input Ratings / Characteristics 

 

Nominal Input  Voltage 

100-240 Vac 

Input  Voltage Range 

90-264 Vac  

Nominal Input  Frequency 

50-60 Hz 

Input  Frequency  Range 

47-63 Hz 

Input  Current 

2.5 A typ. @ 115 Vac, 1.3 A typ. @ 230 Vac 

Efficiency at 100% Load 

86.5% typ. @ 230 Vac 

90.0% typ. @ 230 Vac 

90.5% typ. @ 230 Vac 

Average Efficiency 
(25%, 50%, 75%, 100%) 

88% typ. @ 115 Vac 

88% typ. @ 115 Vac 

88% typ. @ 115 Vac 

No Load Power Consumption 

0.15 W max @ 115 Vac & 

230 Vac 

0.21 W max @ 115 Vac & 

230 Vac 

0.3 W max @ 115 Vac &  

230 Vac 

Max Inrush Current (Cold Start) 

40 A typ. @ 230 Vac 

Power Factor at 100% Load  

> 0.95 @ 115 Vac & 230 Vac 

Leakage Current 

< 0.75 mA @ 240 Vac 

 

 

Output Ratings / Characteristics

*2

 

 

Nominal Output Voltage 

 12 Vdc 

24 Vdc 

48 Vdc 

Factory Set Point Tolerance 

 12 Vdc ± 1% 

24 Vdc ± 1% 

48 Vdc ± 1% 

Output Voltage Adjustment Range 

 10.8-13.2 Vdc 

21.6-26.4 Vdc 

43.2-52.8 Vdc 

Output Current 

 20.0 A 

10.0 A 

5.0 A 

Output Power 

 240 W max 

Line Regulation 

 ± 0.5% @ 115 Vac & 230 Vac 

Load Regulation 

 ± 1.0% 

± 0.5% 

± 0.5% 

PARD

*3

 (20 MHz) 

 < 120 mVpp @ 0°C to +70°C 

< 360 mVpp @ -30°C to 0°C 

< 150 mVpp @ 0°C to +70°C 
< 450 mVpp @ -30°C to 0°C 

< 200 mVpp @ 0°C to +70°C 
< 600 mVpp @ -30°C to 0°C 

Rise Time 

 30 ms typ. @ 115 Vac & 230 Vac 

Start-up Time 

 500 ms typ. @ 115 Vac & 230 Vac 

Hold-up Time 

 20 ms typ. @ 115 Vac (100% load) 

20 ms typ. @ 230 Vac (100% load) 

Dynamic Response  
(Overshoot & Undershoot O/P Voltage) 

 ± 10% @ 115 Vac & 230 Vac input, 10-100% load  

(Slew Rate: 2.5 

A/μs

, 50% duty cycle @ 5 Hz & 10 kHz) 

Start-up with Capacitive Loads 

 8,000 µF Max 

 

8,000 µF Max  
 

3,000 µF Max 

*2 For power will be de-rating from 40°C to 70°C @ 115 Vac & 50°C to 70°C @ 230 Vac, and Vin < 100 Vac, see Engineering Data power de-rating information. 

*3 PARD is measured with an AC coupling mode, 5 cm wires, and in parallel to end terminal with 0.1 

μF ceramic capacitor & 47

 

μF electrolytic ca

pacitor.

 

PSU need to burn in 

around 5 minutes when AMB ≤ 

0°C 

 

 

 

Содержание DRL-12V240W1EN

Страница 1: ...without compromising on quality and reliability The convection cooled LYTE II series will operate full power from 30 C to 50 C then de rating up to 70 C at 230 Vac It can operate in constant current m...

Страница 2: ...Output Voltage 12 Vdc 24 Vdc 48 Vdc Factory Set Point Tolerance 12 Vdc 1 24 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 10 8 13 2 Vdc 21 6 26 4 Vdc 43 2 52 8 Vdc Output Current 20 0 A 10 0 A 5 0 A...

Страница 3: ...r by 1 67 C 115 Vac 50 C de rate power by 2 5 C 230 Vac Input Voltage 100 Vac de rate power by 1 Vac Operating Humidity 20 to 90 RH Non Condensing Operating Altitude 0 to 5 000 Meters 16 400 ft Shock...

Страница 4: ...p Life Time 10 years 230 Vac 50 load 40 C Safety Standards Directives Electrical Safety CB scheme TUV Bauart UL cUL BSMI EAC KC IEC 62368 1 IEC 60950 1 IEC 61010 1 2 201 EN 62368 1 EN 61010 1 2 201 UL...

Страница 5: ...rical Fast Transient Burst IEC61000 4 4 Level 3 Criteria A1 2 kV Surge IEC61000 4 5 Level 4 Criteria A1 Common Mode4 4 kV Differential Mode5 2 kV Conducted IEC61000 4 6 Level 3 Criteria A1 150 kHz 80...

Страница 6: ...Converter Inrush current limit Filter DC DC Converter Output Rectifier Filter Over Temperature Protection PWM Control Over Power Protection Photo Coupler Feedback Control CV CC Photo Coupler Over Volt...

Страница 7: ...4 87 x 1 57 x 4 60 inch Unless otherwise specified tolerance of dimension are 0 5 mm AWG Wire Table Current Rating for PVC Wire 6 AWG 52 5 A 8 AWG 37 5 A 10 AWG 29 0 A 12 AWG 22 5 A 14 AWG 16 5 A 16...

Страница 8: ...when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air temperature is lowered or the load...

Страница 9: ...m the rail Safety Instructions Vertical Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit If mains are not turned OFF there is risk of e...

Страница 10: ...from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush curren...

Страница 11: ...ort circuits When a short circuit is applied the output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit is removed Overvoltage Protection L...

Страница 12: ...r any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the product before placing an order with Delt...

Отзывы: