background image

LYTE II DIN Rail Power Supply 

DRL-240W series / DRL-

V240W1EN

 

TECHNICAL DATASHEET

 

 

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (March 2022, Rev. 04) 

 

5

 

Model Number 

DRL-12V240W1EN 

DRL-24V240W1EN

 

DRL-48V240W1EN 

 

EMC 

 

Emissions (CE & RE)

 

 

  CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3, 

KN 32 (24 V model only) 
Compliance to FCC Title 47, EN/BS EN 61000-6-3: Class B 

Component Power 

Supply for General Use 

 

EN/BS EN 61204-3

 

 

Immunity 

  EN/BS EN 55035, KN 35 (24 V model only), EN/BS EN 61000-6-2  

Compliance to EN/BS EN 61000-6-1 

Electrostatic 

Discharge 

IEC 61000-4-2  Level 4 Criteria A

1)

   

Air Discharge: 15 kV 

Contact Discharge: 8 kV 

Radiated Field 

IEC 61000-4-3  Criteria A

1)  

 

80 MHz – 1 GHz, 10 V/M, 80% Modulation (1 kHz)  

1.4 GHz – 2 GHz, 3 V/M, 80% Modulation (1 kHz)  

2 GHz – 2.7 GHz, 1 V/M, 80% Modulation (1 kHz) 

Electrical Fast 

Transient / Burst 

IEC 61000-4-4  Level 3 Criteria A

1)

   

2 kV 

Surge 

IEC 61000-4-5  Level 4 Criteria A

1)

  

Common Mode

4)

: 4 kV 

Differential Mode

5)

: 2 kV  

Conducted 

IEC 61000-4-6  Level 3 Criteria A

1)

   

150 kHz – 80 MHz, 10 Vrms 

Power Frequency 

Magnetic Fields 

IEC 61000-4-8  Level 4 Criteria A

1)

   

30 A/m 

Voltage Dips and 

Interruptions 

IEC 61000-4-11  0% residual; 1 cycle, Criteria B

2)

 

40% residual; 10 cycle, Criteria C

3)

  

70% residual; 25 cycle, Criteria C

3)

 

Harmonic Current 

Emission 

 

IEC/EN/BS EN 61000-3-2, Class A 

Voltage Fluctuation and 

Flicker 

 

IEC/EN/BS EN 61000-3-3 

Voltage Sag Immunity 

SEMI F47 – 0706 

  80% of 200 Vac 

70% of 200 Vac 

50% of 200 Vac 

160 Vac, 1000 ms 

140 Vac, 500 ms 

100 Vac, 200 ms 

Criteria A

1)

 

Criteria A

1)

 

Criteria A

1)

 

1) Criteria A: Normal performance within the specification limits 

2) Criteria B: Temporary degradation or loss of function which is self-recoverable 

3)

 

Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test) 

4) Asymmetrical: Common mode (Line to earth) 

5) Symmetrical: Differential mode (Line to line)

 

 

Содержание DRL-12V240W1EN

Страница 1: ...without compromising on quality and reliability The convection cooled LYTE II series will operate full power from 30 C to 50 C then de rating up to 70 C at 230 Vac It can operate in constant current m...

Страница 2: ...Output Voltage 12 Vdc 24 Vdc 48 Vdc Factory Set Point Tolerance 12 Vdc 1 24 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 10 8 13 2 Vdc 21 6 26 4 Vdc 43 2 52 8 Vdc Output Current 20 0 A 10 0 A 5 0 A...

Страница 3: ...r by 1 67 C 115 Vac 50 C de rate power by 2 5 C 230 Vac Input Voltage 100 Vac de rate power by 1 Vac Operating Humidity 20 to 90 RH Non Condensing Operating Altitude 0 to 5 000 Meters 16 400 ft Shock...

Страница 4: ...p Life Time 10 years 230 Vac 50 load 40 C Safety Standards Directives Electrical Safety CB scheme TUV Bauart UL cUL BSMI EAC KC IEC 62368 1 IEC 60950 1 IEC 61010 1 2 201 EN 62368 1 EN 61010 1 2 201 UL...

Страница 5: ...rical Fast Transient Burst IEC61000 4 4 Level 3 Criteria A1 2 kV Surge IEC61000 4 5 Level 4 Criteria A1 Common Mode4 4 kV Differential Mode5 2 kV Conducted IEC61000 4 6 Level 3 Criteria A1 150 kHz 80...

Страница 6: ...Converter Inrush current limit Filter DC DC Converter Output Rectifier Filter Over Temperature Protection PWM Control Over Power Protection Photo Coupler Feedback Control CV CC Photo Coupler Over Volt...

Страница 7: ...4 87 x 1 57 x 4 60 inch Unless otherwise specified tolerance of dimension are 0 5 mm AWG Wire Table Current Rating for PVC Wire 6 AWG 52 5 A 8 AWG 37 5 A 10 AWG 29 0 A 12 AWG 22 5 A 14 AWG 16 5 A 16...

Страница 8: ...when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air temperature is lowered or the load...

Страница 9: ...m the rail Safety Instructions Vertical Mounting ALWAYS switch mains of input power OFF before connecting and disconnecting the input voltage to the unit If mains are not turned OFF there is risk of e...

Страница 10: ...from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush curren...

Страница 11: ...ort circuits When a short circuit is applied the output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit is removed Overvoltage Protection L...

Страница 12: ...r any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the product before placing an order with Delt...

Отзывы: