LYTE II DIN Rail Power Supply
DRL-240W series / DRL-
V240W1EN
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (March 2022, Rev. 04)
5
Model Number
DRL-12V240W1EN
DRL-24V240W1EN
DRL-48V240W1EN
EMC
Emissions (CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3,
KN 32 (24 V model only)
Compliance to FCC Title 47, EN/BS EN 61000-6-3: Class B
Component Power
Supply for General Use
EN/BS EN 61204-3
Immunity
EN/BS EN 55035, KN 35 (24 V model only), EN/BS EN 61000-6-2
Compliance to EN/BS EN 61000-6-1
Electrostatic
Discharge
IEC 61000-4-2 Level 4 Criteria A
1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field
IEC 61000-4-3 Criteria A
1)
80 MHz – 1 GHz, 10 V/M, 80% Modulation (1 kHz)
1.4 GHz – 2 GHz, 3 V/M, 80% Modulation (1 kHz)
2 GHz – 2.7 GHz, 1 V/M, 80% Modulation (1 kHz)
Electrical Fast
Transient / Burst
IEC 61000-4-4 Level 3 Criteria A
1)
2 kV
Surge
IEC 61000-4-5 Level 4 Criteria A
1)
Common Mode
4)
: 4 kV
Differential Mode
5)
: 2 kV
Conducted
IEC 61000-4-6 Level 3 Criteria A
1)
150 kHz – 80 MHz, 10 Vrms
Power Frequency
Magnetic Fields
IEC 61000-4-8 Level 4 Criteria A
1)
30 A/m
Voltage Dips and
Interruptions
IEC 61000-4-11 0% residual; 1 cycle, Criteria B
2)
40% residual; 10 cycle, Criteria C
3)
70% residual; 25 cycle, Criteria C
3)
Harmonic Current
Emission
IEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and
Flicker
IEC/EN/BS EN 61000-3-3
Voltage Sag Immunity
SEMI F47 – 0706
80% of 200 Vac
70% of 200 Vac
50% of 200 Vac
160 Vac, 1000 ms
140 Vac, 500 ms
100 Vac, 200 ms
Criteria A
1)
Criteria A
1)
Criteria A
1)
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Temporary degradation or loss of function which is self-recoverable
3)
Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)