C h a p t e r 5 P a r a m e t e r s a n d F u n c t i o n s
5 - 5 7
_5
3E8
41001
Time of minimum total
harmonic distortion for
phase current
unbalance
Hour: 00–23
Minute: 00–59
byte
Hour,
Minute
2
R
3E9
41002
Second: 00–59
word Second
4. Alarm
:
0400 – 04FF
400
41025
Alarm status of over
current
0: Cleared
1: Triggered
word
2
R
401
41026
Alarm times of over
current
1–255
word Times
2
R
402
41027
Alarm date of over
current
Year: 00–99
Month: 1–12
byte
Year,
Month
2
R
403
41028
Date: 1–31
word
Date
404
41029
Alarm time of over
current
Hour: 00–23
Minute: 00–59
byte
Hour,
Minute
2
R
405
41030
Second: 00–59
word Second
406
41031
Alarm status of under
current
0: Cleared
1: Triggered
word
2
R
407
41032
Alarm times of under
current
1–255
word Times
2
R
408
41033
Alarm date of under
current
Year: 00–99
Month: 1–12
byte
Year,
Month
2
R
409
41034
Date: 1–31
word
Date
40A
41035
Alarm time of under
current
Hour: 00–23
Minute: 00–59
byte
Hour,
Minute
2
R
40B
41036
Second: 00–59
word Second
Содержание DPM-C530
Страница 2: ......
Страница 3: ......
Страница 10: ...DPM C530 Operation Manual 1 4 _1 _1 MEMO...
Страница 16: ...DPM C530 Operation Manual 2 6 _2 2 4 Dimensions Front Unit mm Back Unit mm...
Страница 35: ...5 1 5 Chapter 5 Parameters and Functions Table of Contents 5 1 Overview of Parameters 5 2...
Страница 117: ...6 1 Chapter 6 Error Codes Table of Contents 6 1 Error Codes 6 2 6 2 Alarm Types 6 2 6...
Страница 120: ...DPM C530 Operation Manual 6 4 _6 Memo...
Страница 121: ...A 1 Appendix A Accessories Table of Contents A 1 DCT1000 Series A 2 A 2 DCT2000 Series A 4 12 A...