DPM-C501L/C502 Operation Manual
2-8
_2
2.5
DI/DO
Digital Input (DI)
Connector type
Removable Terminal Block
Number of inputs
4 (dry contact)
Galvanic isolation
4000 VAC 1 min
Input voltage / current
10 VDC, 5 mA
Response time
OFF → ON
10 ms ±10%
ON → OFF
15 ms ±10%
Electrical isolation
Optical coupler
Screw turning torque
8.0 kgf-cm (0.8 Nꞏm
)
Cable diameter
12 ~ 24 AWG
Digital Output (DO)
Connector type
Removable Terminal Block
Number of outputs
2
Galvanic isolation
4000 VAC 1 min
Output type
Relay
Output voltage / current
240 VAC / 24 VDC
Leakage current
0 uA
Maximum
response time
OFF → ON
50ms±10%
ON → OFF
Screw turning torque
8.0 kgf-cm
(
0.8 Nꞏm
)
Cable diameter
12 ~ 24 AWG