ASDA-B2-F Parameters
September, 2015
7-57
7
Read parameters: shows the DI status after combination
Write parameters: writes the software SDI status (The function of this parameter is the same
whether it is written via panel or communication.)
Example: The value of reading P4-07 is 0x0011, which means DI1 and DI5 are ON; the value of
writing P4-07 is 0x0011, which means software SDI1 and SDI5 are ON
Please refer to P2-10 ~ P2-14 for function program of digital input pin DI (DI1~DI5).
P4-08
★
PKEY
Input Status of the Drive Keypad (Read-only)
Address: 0410H
0411H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: -
Control
Mode:
ALL
Unit: -
Range: (Read-only)
Format: HEX
Data Size: 16-bit
Settings:
The aim is to check if the five keys MODE, UP, DOWN, SHIFT and SET can work normally.
P4-09
★
PKEY
Digital Output Status (Read-only)
Address: 0412H
0413H
Operational
Interface:
Panel / Software
Communication
Related
Section:
4.4.5
Default: -
Control
Mode:
ALL
Unit: -
Range: 0 ~ 0x1F
Format: HEX
Data Size: 16-bit
Settings:
There is no difference between reading via panel or communication.
P4-10
■
CEN
Adjustment Selection
Address: 0414H
0415H
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: 0
Control
Mode:
ALL
Unit: -
Range: 0 ~ 6
Format: DEC
Data Size: 16-bit
Settings:
0: Reserved
4: Execute the adjustment of current detector (W
phase) hardware offset
1: Reserved
5: Execute the adjustment of 1 ~ 4 hardware
offset
2: Reserved
6: Execute the adjustment of IGBT ADC
3: Execute the adjustment of current detector (V
phase) hardware offset
-
Note:
The adjustment function needs to be enabled by the setting of parameter P2-08. When adjusting, the external
wiring which connects to torque needs to be removed completely and must be in Servo Off status.
P4-11~P4-14
Reserved
P4-15
COF1
Current Detector (V1 Phase) Offset Adjustment
Address: 041EH
041FH
Operational
Interface:
Panel / Software
Communication
Related
Section:
-
Default: Factory default
Control
Mode:
ALL
Unit: -
Range: 0 ~ 32767
Format: DEC
Data Size: 16-bit
Settings:
Manually adjust the hardware offset. The adjustment function needs to be enabled by the setting of
parameter P2-08. It is not suggested to adjust the auxiliary adjustment. This parameter cannot be
reset.
Содержание ASD-B2-0121-F
Страница 3: ...September 2015 This page is intentionally left blank...
Страница 9: ...VI September 2015 This page is intentionally left blank...
Страница 17: ...Inspection and Model Explanation ASDA B2 F 1 8 September 2015 1 This page is intentionally left blank...
Страница 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Страница 117: ...Control Mode of Operation ASDA B2 F 6 28 September 2015 6 This page is intentionally left blank...
Страница 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Страница 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Страница 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Страница 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Страница 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...
Страница 265: ...Appendix A Specifications ASDA B2 F A 26 September 2015 A This page is intentionally left blank...
Страница 287: ...Appendix C Basic Inspection and Maintenance ASDA B2 F C 4 September 2015 C This page is intentionally left blank...