ASDA-B2-F Parameters
September, 2015
7-63
7
Table 7.1 Function Description of Digital Input (DI)
Setting Value: 0x02
DI Name
Function Description of Digital Input (DI)
Trigger
Method
Control
Mode
ARST
After the cause of alarm has been removed, when this DI is ON, it
means the alarm shown on the servo drive has been cleared.
Rising
edge
triggered
ALL
Setting Value: 0x03
DI Name
Function Description of Digital Input (DI)
Trigger
Method
Control
Mode
GAINUP
In speed and position modes, when this DI is ON (P2-27 should be set
to 1), the gain switches to the one multiplies the switching rate.
Level
triggered
DMCNET,
Sz
Setting Value: 0x14, 0x15
DI Name
Function Description of Digital Input (DI)
Trigger
Method
Control
Mode
SPD0
SPD1
Internal Speed Command Selection (1~4)
Speed
Command
Number
DI Signal of
CN1
Command
Source
Content
Range
SPD1 SPD0
S1 0
0
Mode Sz
N/A
Speed
command is 0
0
S2 0
1
Internal Register
Parameter
P1-09
+/- 5000
r/min
S3 1
0
P1-10
+/- 5000
r/min
S4 1
1
P1-11
+/- 5000
r/min
Level
triggered
Sz
Setting Value: 0x16, 0x17
DI Name
Function Description of Digital Input (DI)
Trigger
Method
Control
Mode
TCM0
TCM1
Internal Torque Command Selection (1~4)
Torque
Command
Number
DI Signal of
CN1
Command
Source
Content
Range
TCM1 TCM0
T1 0
0
Mode Tz
N/A
Torque
command is 0
0
T2 0
1
Internal Register
Parameter
P1-12
+/- 300 %
T3
1
0
P1-13
+/- 300 %
T4
1
1
P1-14
+/- 300 %
Level
triggered
Tz
Setting Value: 0x21
DI Name
Function Description of Digital Input (DI)
Trigger
Method
Control
Mode
EMGS
When this DI is ON, the motor stops urgently.
Level
triggered
ALL
Setting Value: 0x22
DI Name
Function Description of Digital Input (DI)
Trigger
Method
Control
Mode
NL
(CWL)
Reverse inhibit limit (contact b)
Level
triggered
ALL
Содержание ASD-B2-0121-F
Страница 3: ...September 2015 This page is intentionally left blank...
Страница 9: ...VI September 2015 This page is intentionally left blank...
Страница 17: ...Inspection and Model Explanation ASDA B2 F 1 8 September 2015 1 This page is intentionally left blank...
Страница 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Страница 117: ...Control Mode of Operation ASDA B2 F 6 28 September 2015 6 This page is intentionally left blank...
Страница 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Страница 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Страница 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Страница 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Страница 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...
Страница 265: ...Appendix A Specifications ASDA B2 F A 26 September 2015 A This page is intentionally left blank...
Страница 287: ...Appendix C Basic Inspection and Maintenance ASDA B2 F C 4 September 2015 C This page is intentionally left blank...