ASDA-B2-F Parameters
September, 2015
7-25
7
Settings:
Internal Speed Command 2: The setting of the 2
nd
internal speed command
Internal Speed Limit 2: The setting of the 2
nd
internal speed limit
Example of inputting internal speed limit:
Speed Limit Setting
Value of P1-10
Allowable Speed
Range
Forward Speed
Limit
Reverse Speed
Limit
1000
-100 ~ 100 r/min
100 r/min
-100 r/min
-1000
P1-11
SP3
Internal Speed Command 3 / Internal Speed Limit
3
Address: 0116H
0117H
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.3.1
Default: 3000
Control
Mode:
Sz (Internal Speed Command) / Tz
(Internal Speed Limit)
Unit: 0.1 r/min
Range: -60000 ~ +60000
Format: DEC
Data Size: 32-bit
Example:
Internal Speed Command: 120 = 12 r/min
Internal Speed Limit: Positive value and negative value are the same. Please refer to the
following description.
Settings:
Internal Speed Command 3: The setting of the 3
rd
internal speed command
Internal Speed Limit 3: The setting of the 3
rd
internal speed limit
Example of inputting internal speed limit:
Speed Limit Setting
Value of P1-11
Allowable Speed
Range
Forward Speed
Limit
Reverse Speed
Limit
1000
100 ~ 100 r/min
100 r/min
-100 r/min
-1000
P1-12
TQ1
Internal Torque Command 1 / Internal Torque
Limit 1
Address: 0118H
0119H
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.4.1
Default: 100
Control
Mode:
Tz (Internal Torque Command) /
DMCNET, Sz (Internal Torque
Limit)
Unit: %
Range: -300 ~ +300
Format: DEC
Data Size: 16-bit
Example:
Internal Torque Command: 30 = 30 %
Internal Torque Limit: Positive value and negative value are the same. Please refer to the
following description.
Settings:
Internal Torque Command 1: The setting of the 1
st
internal torque command
Internal Torque Limit 1: The setting of the 1
st
internal torque limit
Example of inputting internal torque limit:
Torque Limit Setting
Value of P1-12
Allowable Torque
Range
Forward Torque
Limit
Reverse Torque
Limit
30
-30 ~ 30 %
30 %
-30 %
-30
P1-13
TQ2
Internal Torque Command 2 / Internal Torque
Limit 2
Address: 011AH
011BH
Operational
Interface:
Panel / Software
Communication
Related
Section:
6.4.1
Default: 100
Control
Mode:
Tz (Internal Torque Command) / Sz
(Internal Torque Limit)
Unit: %
Range: -300 ~ +300
Format: DEC
Data Size: 16-bit
Example:
Internal Torque Command: 30 = 30 %
Internal Torque Limit: Positive value and negative value are the same. Please refer to the
following description.
Settings:
Internal Torque Command 2: The setting of the 2
nd
internal torque command
Internal Torque Limit 2: The setting of the 2
nd
internal torque limit
Содержание ASD-B2-0121-F
Страница 3: ...September 2015 This page is intentionally left blank...
Страница 9: ...VI September 2015 This page is intentionally left blank...
Страница 17: ...Inspection and Model Explanation ASDA B2 F 1 8 September 2015 1 This page is intentionally left blank...
Страница 29: ...Installation ASDA B2 F 2 12 September 2015 2 This page is intentionally left blank...
Страница 117: ...Control Mode of Operation ASDA B2 F 6 28 September 2015 6 This page is intentionally left blank...
Страница 185: ...Parameters ASDA B2 F 7 68 September 2015 7 This page is intentionally left blank...
Страница 199: ...Communications ASDA B2 F 8 14 September 2015 8...
Страница 201: ...Communications ASDA B2 F 8 16 September 2015 8 This page is intentionally left blank...
Страница 217: ...Troubleshooting ASDA B2 F 9 16 September 2015 9 This page is intentionally left blank...
Страница 239: ...Absolute System ASDA B2 F 10 22 September 2015 10 This page is intentionally left blank...
Страница 265: ...Appendix A Specifications ASDA B2 F A 26 September 2015 A This page is intentionally left blank...
Страница 287: ...Appendix C Basic Inspection and Maintenance ASDA B2 F C 4 September 2015 C This page is intentionally left blank...