PAR AL LEL OP ER A TION OF FAST PRO-
GRAMMING VER SIONS:
•
Master / Slave op eration is not rec ommended.
•
Nor mal par al lel op er a tion can give prob lems, each com bi na -
tion has to be tested first in com bination with the load.
12)
MASTER / SLAVE MIXED SERIES / PAR ALLEL
OP ER A TION
•
For complex com binations as mixed se ries - parallel al ways
use the
MASTER / SLAVE SERIES ADAPTER
(
δ
-prod uct)
.
•
See fig. 4 - 14 for an ex ample of how to connect 2 units in se -
ries in par allel with 2 units in se ries, controlled by 1 mas ter.
•
On the parallel slave1, fully open the CV-potmeter.
•
Note: A Mas
ter / Slave combination can al
ways be pro
-
grammed, also with the
IEEE488 / RS232
con trol ler
(
PSC-488 mod ule / PSC-232
(both
δ
-prod ucts)
).
fig. 4 - 13
Master / Slave parallel connections
fig. 4 - 14
Master / Slave mixed series - parallel connections with
two
MASTER / SLAVE SERIES ADAPTERS