DELTA ELEKTRONIKA BV

SM3000

Page 4 - 2

OPERATING  MAINTENANCE  TROUBLE SHOOTING  CALIBRATING

1991, rev. May 2008

5)

STATUS OUT PUTS

The status outputs have a separate Ø con nection (pin 8) to
avoid un wanted offsets in the pro gramming. This pin is pro -
tected with a 650 mA fuse (F601 on P432).

6)

RE MOTE SENSING

Remove the links on the SENSE BLOCK (on rear panel) and
connect sense leads (thin

shielded

 mea suring wires) to S+

and S– (see fig 4 - 5 and fig. 4 - 6).

With remote sensing the voltage on the load can be kept con -
stant. The voltage drop in the load leads will be com pensated.
This feature is not rec ommended for normal use, be cause it
can eas ily give prob lems.

Max. 2 V per load lead can be compensated. Note that the
voltage drop in the leads de creases the max. output voltage
rating. In fig. 4 - 7  can be seen that on a 15 V power sup ply
only 11 V will be available on the load when 2x 2 V com pensa-
tion is used.

In or der to pre vent in terference it is ad visable to twist the
sense leads. To min imize the inductance in the load leads
keep the leads close to each other. The in ductance of the
loads leads could give a prob lem with pul sating loads. In this
case a large electrolytic ca pacitor (Cd) in se ries with a damp -
ing re sistor (Rd) both in parallel with the load will help (see fig.
4 - 6). Check that the ca pacitor Cd in combination with the load 
leads and re sistor Rd forms a well damped cir cuit.

Since the 

volt me ter

 is in ternally con nected to the sens ing ter -

mi nals, it will au to mat i cally in di cate the

voltage on the load

.

Note that the voltage mea sured on the load will be lower than
on the out put terminals.

The Over Volt age Pro tector mea sures the volt age on the out -
put terminals, so the OVP set ting should be in creased by the
total voltage drop in the load leads.

7)

BAT TERY CHARGER

The CV / CC reg ulated power supplies are ideal battery charg-
ers. Once the output is set at the correct voltage the bat tery
will charge con stantly with out over charging. This can be use -
ful for emer gency power systems.

Pro tec tive mea sures

Use a CIR CUIT BREAKER in se ries in or der to pro tect the
power sup 

ply from

ac ci den tal re 

verse con 

nec tion

 (see

fig. 4 - 8). The cir cuit breaker should have a DC voltage rat ing
2x the bat tery voltage. Use the very fast type (Z), a type meant 
for pro tect ing semi con duc tors.
The unit has a re verse di ode in par allel with the out put, this di -
ode and the wir ing can not with stand the thou sands of am-
peres sup plied by a wrongly connected battery.

Suggested circuit breakers for pro tection power supply

Model

Type num ber
circuit breaker

Brand Re marks

SM 15-200 D HTI102 B 100

GE

2 poles par allel

SM 30-100 D HTI102 B 100

GE

SM 45-70 D

HTI102 B 100

GE

SM 70-45 D

S281 UC-Z 50

ABB

SM 120-25 D S281 UC-Z 25

ABB

SM 300-10 D S282  UC-Z  10

ABB

2 poles in se ries,

ex tra par al lel
di ode on
out put needed
=OP TION P023

Re mote sens ing

 can not be rec ommended, be cause it easily

causes de fects in side the power sup ply in case of wrong con -
nec tion.
If you re ally need re mote sensing, please use the cir cuit (see
fig. 4 - 9). The in ternal cir cuit can be protected by rel atively
small anti-parallel di odes. To pro tect the anti-parallel di odes,
please con nect the fuses in series as in dicated in  fig. 3 - 9 . A
practical choice for the fuses is 250 mA, the di odes can be any 
normal 3 or 5 A type.

fig. 4 - 5

Lo cal sens ing

fig. 4 - 6

Remote sensing with shielded wires

fig. 4 - 7

Remote sensing, voltage drop in load leads sub -

tracts from max. output

fig. 4 - 8

Charging battery with a circuit breaker in se ries

fig. 4 - 9

Protecting sense wires with di odes

Содержание SM 120-25 D

Страница 1: ...5 200D SM 30 100D SM 45 70D SM 70 45D SM 120 25D SM 300 10D SM 3000 series Elso Philips Service Jilemnick ho 2 911 01 Tren n tel 421 32 6582410 7431690 fax 421 32 6582592 email elso elso sk web www el...

Страница 2: ...he protective earth terminal must be connected to the safety electrical ground before another connection is made Any interruption of the protective ground conductor or disconnection of the protective...

Страница 3: ...l Shock Instruction manual symbol The instrument will be marked with this symbol when it is necessary for the user to refer to the instruction manual Protective ground conductor terminal o Off supply...

Страница 4: ...r cuit 2 INPUT VOLTAGE The power supplies have a wide input volt age range The units need a 3 phase input voltage but no neutral connection is required The units can also operate on one phase but at 9...

Страница 5: ...lways use a shielded ca ble for programming The inputs have a protection circuit formed by a series resistor and a parallel zener see fig 3 7 The capacitor limits the speed to a safe value Note that t...

Страница 6: ...h 13 PROGRAMMING SPEED The response time is measured with a step waveform at the CV prog input Programming from a low to a high output voltage is nearly load independent but programming down to a low...

Страница 7: ...gh energy pulse of about 300 V If there is an electrical connection between the output and the input through the oscilloscope you will get a false reading The suppression for the SM120 25D is lower bu...

Страница 8: ...tch shuts down the output in case of insufficient cooling After cooling down the unit will start working again The thermal protection circuit protects 2 parts separately in the unit the switching tran...

Страница 9: ...ecommended for more than 3 units or in combination with Fast Programming option Consult factory for a solution 29 REMOTE SENSING The voltage at the load can be kept constant by remote sensing This fea...

Страница 10: ...re and full load the fan will run at a very low speed The fan does not operate on no load Normally at 50 C ambient and full load the fan will not work at full speed Since the fan is over rated it will...

Страница 11: ...TER circuit so no large inrush cur rent will flow As soon as the voltage is sufficiently high the power supply starts working and the series resistor is bypassed by a relay contact The operating switc...

Страница 12: ...recom mended to set the OVP on 24 3 27 V Check that the cooling of the unit is not obstructed 2 ANALOG PROGRAMMING Put the appropriate switch es in the position PROGRAM Connect the programming voltage...

Страница 13: ...put terminals so the OVP setting should be increased by the total voltage drop in the load leads 7 BATTERY CHARGER The CV CC regulated power supplies are ideal battery charg ers Once the output is set...

Страница 14: ...ecommended for more than 4 units consult factory for using more than 4 power supplies in parallel First connect output terminals and test system in normal paral lel operation Ensure that all power con...

Страница 15: ...PERATION For complex combinations as mixed series parallel always use the MASTER SLAVE SERIES ADAPTER product See fig 4 14 for an example of how to connect 2 units in se ries in parallel with 2 units...

Страница 16: ...supply to dry before switching it on again 3 GALVANIC INDUSTRY For using the power supplies in the galvanic industry it is strongly recommended to take precautions against an aggressive environ ment...

Страница 17: ...current is flowing through pin 1 of the prog connector Please check why current is flowing through pin 1 see also next paragraph 4 and fig 4 17 4 PROGRAMMING OFFSETS Unwanted offsets in the programmi...

Страница 18: ...not try to re pair P430 except for D400 D401 F400 and F401 but send P430 for repair or ask for replacement 10 CHECK POINTS IN CASE OF A SERIOUS FAILURE Check output diodes Defective diodes give a sho...

Страница 19: ...put with exactly 5 00 V Set output voltage to a low value en suring the power supply is in CC mode Measure the output current with an ac curate shunt Calibrate the current with R686 exactly on the rat...

Страница 20: ...l Journal of the European Communities EN 61204 3 EMC low voltage power supplies EN 61000 6 3 Generic Emissions residential light industrial EN 55022 Radiated and conducted Class B EN 61000 3 3 Voltage...

Отзывы: