3. Off-Grid Support Hybrid Energy Storage System (Internal ATS Mode)
The key feature of this system is that it can support off-grid application and
the PV inverter can continue generating power during power failure. In this
application, the auto contactor is not necessary as it applies the internal
contactor of BX6.3_AC100. Due to hardware limitation, this system can only
provide max. power of 5 kVA to the main load. For the PV inverter connected
at the SPS port, not only support Delta PV inverters, 3rd party PV inverter is
compatible. For Delta PV inverters, FW updates might be performed to get
access to this function. Please refer to
Table5-1
for the requirements of inverter.
Power rating should not exceed 5kVA.
1
3
2
4
*DC1 is necessary in South Australia, it may not be required in other regions.
Microwave
Cooking
Air
Conditioner
Washing
Machine
Light
TV
Surveillance
Camera
Charging
Distribution Panel
Grid
CT
CT
Wi-Fi
P2P
BX6.3_AC100
HXA
BX6.3_EX100
SPS
AC
DC
DC
Grid
CT
Main Load
Critical Load
3rd Party
Monitoring Plaform
LAN
Ethernet
P2P
MyDeltaSolar Cloud Service (Monitoring)
Cloud
DC1 *
Data Collector
Solar Panel
Figure 5-3 : Off-Grid Support Hybrid Energy Storage System (Internal ATS Mode)
Table 5-1 : Requirements for the PV inverter
Should compliant with regulation AS4777.2
P(f) function should be enabled all the time.
3rd party inverter with built-in external CT might
need to be able to turn off its CT detection.
Requirements for the PV inverter in application 3. and 4.
DeltaSolar (App)
Production
Feed-in
Consumption
3.22 kW
0.22 kW
3.00 kW
Karapinar
38.8 kWh
-- kWh
IBARAKI
Tainan,Taiwan
20.4 kWh
Chiayi,Taiwan
Floating
Tainan,Taiwan
Feed-in
3.22
3.00
54
System application