1. The CT can be opened.
2. Take the CT clip on the Line conductor wire.
3. Please refer to the symbol on the CT clamp and make sure the CT clamp is
installed in the correct direction as the figure below.
4. Connect the CT wires to the device.
5. Connect the CT cable to the connector on the Comm. Module as the figure below.
L
N
Main Breaker
Energy meter
of the electric
utility
company
CT label direction
Grid
BX6.3/12.6_AC100
3.11 Installation of External CT Clamp.
BX6.3_AC100 has an built-in power meter with an external CT clamp.
With this power meter, system can achieve the function bellows:
1. Measure the amount of feed-in power and the power-consumption of the house.
2. To perform the export control function in compatible with another PV inverter
in the system.
Figure 3-16 : Current Transformer installation
DANGER : ELECTRICAL HAZARD!!
- The product is intended to be installed and operated by qualified personnel or
service personnel only.
- Do not power up the device before installation is complete.
- All circuit breakers must be in the OFF position before commencing installation.
37